Difference between revisions of "VTube-LASER v2.8.2"
From ATTWiki
(→25px NEW: DCF (Dual Cylinder Fit) for SPLIT BEND) |
(→25px RETURNED FEATURE: ARM AS A MOUSE) |
||
(7 intermediate revisions by one user not shown) | |||
Line 40: | Line 40: | ||
<br><br> | <br><br> | ||
− | ==[[image:Check.jpg|25px]] RETURNED: ARM AS MOUSE== | + | ==[[image:Check.jpg|25px]] RETURNED FEATURE: ARM AS A MOUSE== |
<table cellpadding=10 width=900> | <table cellpadding=10 width=900> | ||
Line 46: | Line 46: | ||
<td width=300> | <td width=300> | ||
We believed that none of our users used the "Arm as a Mouse" feature that allows the FARO arm to be used as a mouse - so we removed it from a previous version.<br><br> | We believed that none of our users used the "Arm as a Mouse" feature that allows the FARO arm to be used as a mouse - so we removed it from a previous version.<br><br> | ||
− | We were wrong. It is now added back into the interface. | + | We discovered that we were wrong. It is now added back into the interface.<br><br> |
+ | [[image:faro_scanner_v6.png|400px|right]]<br><br> | ||
<td> | <td> | ||
</td> | </td> | ||
<td> | <td> | ||
+ | [[image:vtube-laser_v2.8.1 arm as a mouse.png]]<br><br> | ||
+ | |||
</tr> | </tr> | ||
</table> | </table> | ||
<br><br> | <br><br> | ||
− | |||
==[[image:Check.jpg|25px]] Other Features and Fixes== | ==[[image:Check.jpg|25px]] Other Features and Fixes== | ||
Line 61: | Line 63: | ||
<td width=400> | <td width=400> | ||
* New sound files were not being copied during the install of 2.8.1. This is now fixed in this version.<br><br> | * New sound files were not being copied during the install of 2.8.1. This is now fixed in this version.<br><br> | ||
− | * The new guide window notifications were staying on the screen too long and obstructing the DRO. This has been fixed so that the guide box will automatically disappear the moment any scanned or point data is received.<br><br> | + | * The new guide window notifications were staying on the screen too long and obstructing the DRO. This has been fixed so that the guide box will automatically disappear the moment any scanned or point data is received inside VTube-LASER.<br><br> |
− | * We made a change to 321 Plane-Line-Point that stopped it from working. This has been fixed. | + | * We made a change to 321 Plane-Line-Point that stopped it from working in 2.8. This has been fixed in this version. |
<td> | <td> | ||
</td> | </td> |
Latest revision as of 02:39, 12 May 2017
Revision 2.8.2Original Release Date: May 11, 2017
|
Contents |
NEW: DCF (Dual Cylinder Fit) for SPLIT BEND
Split Bend is used to measure 180-degree bends. VTube-LASER now uses the DCF (Dual Cylinder Fit) features in Split Bend.
|
RETURNED FEATURE: ARM AS A MOUSE
We believed that none of our users used the "Arm as a Mouse" feature that allows the FARO arm to be used as a mouse - so we removed it from a previous version. |
Other Features and Fixes
|
Other Pages
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.
- See the tutorial on DCF - Dual Cylinder Fit
- See the tutorial on DCP - Diameter Cut Planes
- See VTube-LASER Cut Planes
- See How to Measure Tubes Attached to an Evaporator with the DCP Feature