Difference between revisions of "VTube-LASER Bender Corrections"
(→"Setup the Bender" - FOR SENDING NEW DATA) |
(→"Bidirectional Communication" - FOR CORRECTIONS) |
||
(2 intermediate revisions by one user not shown) | |||
Line 73: | Line 73: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | With the right protocol at the bender, VTube-LASER can recall data from the bender, and send both setup and correction data to the bender.<br><br> | + | With the right protocol at the bender, VTube-LASER can recall data from the bender, and send both setup and correction data to the bender.<nowiki>*</nowiki><br><br> |
* Operators typically press the "1" button to recall data to be sure the data in the blue columns match the data in the bender.<br><br> | * Operators typically press the "1" button to recall data to be sure the data in the blue columns match the data in the bender.<br><br> | ||
* Then they press "2" to send the orange columns to the bender as corrected data.<br><br> | * Then they press "2" to send the orange columns to the bender as corrected data.<br><br> | ||
* Press "3" to clear the adjustment data after a correction as it should only be used one time.<br><br> | * Press "3" to clear the adjustment data after a correction as it should only be used one time.<br><br> | ||
* For benders that can't respond to a recall (1 above), they can recalculate the blue columns by clearing and placing the adjustments back into the blue columns automatically.<br><br> | * For benders that can't respond to a recall (1 above), they can recalculate the blue columns by clearing and placing the adjustments back into the blue columns automatically.<br><br> | ||
+ | |||
+ | <nowiki>*</nowiki> Not all protocols require a RECALL before sending CORRECTIONS. | ||
+ | |||
</td> | </td> | ||
<td width=300> | <td width=300> |
Latest revision as of 20:06, 16 July 2018
|
Contents |
Correcting a Bender
You can see the deviation in this part. The transparent yellow tolerance envelopes indicate that the part is outside of the deviation tolerance allowed (in this case 0.039" or 1 mm). |
BENDER SETUP Window
VTube-LASER uses the Bender Setup screen to control the values in up to 100 connected benders.
|
"Setup the Bender" - FOR SENDING NEW DATA
Use the "SETUP THE BENDER" section on the right to send new data. |
"Bidirectional Communication" - FOR CORRECTIONS
With the right protocol at the bender, VTube-LASER can recall data from the bender, and send both setup and correction data to the bender.*
* Not all protocols require a RECALL before sending CORRECTIONS. |
Correction Damping
VTube-LASER uses a unique correction damping feature for situations were corrections tend to over correct. |
Other Pages
- See How to Setup VTube for Supravision Network Communication
- Back to VTube-LASER