Difference between revisions of "VTube-STEP v2.9.11"
(→25pxNEW - STAR Bender Setup From Solid Model Through a Network) |
(→25pxFIX- SPLIT BENDS ACTIVE IN ABSOLUTE LRA DATA GRID) |
||
(6 intermediate revisions by one user not shown) | |||
Line 22: | Line 22: | ||
<br><br> | <br><br> | ||
__TOC__ | __TOC__ | ||
+ | |||
+ | |||
+ | ==[[image:Check.jpg|25px]]NEW - YELLOW BAR MARKS SPLIT BENDS ACTIVE IN LRA DATA GRID== | ||
+ | |||
+ | <table cellpadding=10 width=700> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=400> | ||
+ | |||
+ | Split Bends are used to compress two adjacent bends into one larger bend. This is how VTube handles 180-degree (or greater) bends.<br><br> | ||
+ | |||
+ | It's important for operators to know when Split Bend is active in VTube-STEP or VTube-LASER (for 180-degree or greater bends). VTube compresses the bender data with Split Bends active and measures the part differently.<br><br> | ||
+ | So VTube now shows a yellow shaded row in the LRA data grids where a Split Bend is switched on. | ||
+ | <br><br> | ||
+ | |||
+ | For details on Split Bends, see [[VTube-LASER Split Bend Feature]] | ||
+ | </td> | ||
+ | |||
+ | <td> | ||
+ | |||
+ | [[image:vtl_2.9.11_splitbend_lra_row_not active.png|400px]]<br><br> | ||
+ | [[image:vtl_2.9.11_splitbend_lra_row_shade.png|400px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ==[[image:Check.jpg|25px]]FIX - SPLIT BENDS ACTIVE IN ABSOLUTE LRA DATA GRID== | ||
+ | |||
+ | <table cellpadding=10 width=700> | ||
+ | <tr valign=top> | ||
+ | |||
+ | <td width=400> | ||
+ | Absolute LRA data is also known as Military Spec bender data. It is still used by the USAF, and possibly other branches of the US military.<br><br> | ||
+ | |||
+ | If you use the Absolute LRA data with Split Bends, then this update is important for you because we discovered a bug in the absolute (as opposed to incremental) LENGTH calculation when Split Bends were enabled. | ||
+ | <br><br> | ||
+ | The absolute LENGTH calculations after the split bend would be off by half the arc length of the combined split bend. This has been fixed and double-checked against current Mil Spec charts.<br><br> | ||
+ | |||
+ | See [[VTube Reverse Calc from MIL-D-9898C Absolute Bender Data to Centerline XYZ Data]] for an in-depth article on this bender format. | ||
+ | </td> | ||
+ | |||
+ | <td> | ||
+ | |||
+ | [[image:vtl_2.9.11_splitbend_lra_row_absolute_lra.png|400px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
==[[image:Check.jpg|25px]]NEW - STAR Bender Setup From Solid Model Through a Network== | ==[[image:Check.jpg|25px]]NEW - STAR Bender Setup From Solid Model Through a Network== | ||
Line 35: | Line 82: | ||
[[image:StarEvoSplash.png|200px]]<br><br> | [[image:StarEvoSplash.png|200px]]<br><br> | ||
− | Use this new feature to import solid models into | + | Use this new feature to import solid models into STAR bender controls.<br><br> |
− | See [[VTube | + | See [[VTube STAR SVNet Bender Communications]] for more details. |
</td> | </td> | ||
Line 43: | Line 90: | ||
<td> | <td> | ||
− | [[image:vtl_v2.9. | + | [[image:vtl_v2.9.11 STAR Send New Complete.png|600px]] |
</td> | </td> | ||
</tr> | </tr> |
Latest revision as of 03:45, 28 July 2018
Revision 2.9.11Release Date: July 20, 2018
|
Contents |
NEW - YELLOW BAR MARKS SPLIT BENDS ACTIVE IN LRA DATA GRID
Split Bends are used to compress two adjacent bends into one larger bend. This is how VTube handles 180-degree (or greater) bends. It's important for operators to know when Split Bend is active in VTube-STEP or VTube-LASER (for 180-degree or greater bends). VTube compresses the bender data with Split Bends active and measures the part differently. For details on Split Bends, see VTube-LASER Split Bend Feature |
FIX - SPLIT BENDS ACTIVE IN ABSOLUTE LRA DATA GRID
Absolute LRA data is also known as Military Spec bender data. It is still used by the USAF, and possibly other branches of the US military. If you use the Absolute LRA data with Split Bends, then this update is important for you because we discovered a bug in the absolute (as opposed to incremental) LENGTH calculation when Split Bends were enabled.
See VTube Reverse Calc from MIL-D-9898C Absolute Bender Data to Centerline XYZ Data for an in-depth article on this bender format. |
NEW - STAR Bender Setup From Solid Model Through a Network
We added the STAR SVNet protocol that allows VTube-STEP to send NEW data to the STAR benders through a network connection.
See VTube STAR SVNet Bender Communications for more details. |
Other Pages
- Back to VTube-LASER
- Back to VTube Software Updates (for LASER Mode)
- See also VTube-STEP
- See also VTube-STEP Revisions
- See VTube-LASER Customer Support Page to download the latest version.