Difference between revisions of "Importing a .STP File"

From ATTWiki
Jump to: navigation, search
(STEP 4)
 
(8 intermediate revisions by one user not shown)
Line 37: Line 37:
 
</td>
 
</td>
 
<td>
 
<td>
[[image:vtube-v4 import
+
[[image:vtube-v4 import.png|400px]]
.png|400px]]
+
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 49: Line 48:
 
</td>
 
</td>
 
<td>
 
<td>
[[image:vtube_v3.2_CHSpart.png|600px]]
+
[[image:vtube_v4demo6.png|600px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 59: Line 58:
 
To collect parametric data, an operator can either autobuild or manually collect features.
 
To collect parametric data, an operator can either autobuild or manually collect features.
  
For Autobuild
+
For [http://www.advancedtubular.wiki/index.php/Autobuild Autobuild].
  
 
For Manual Collection
 
For Manual Collection
Line 65: Line 64:
 
</td>
 
</td>
 
<td>
 
<td>
[[image:vtube_v3.2_CHS.png|600px]]
+
[[image:vtube_v4autobuild.png|600px]]
 +
 
 +
[[image:vtube_v4manual.png|600px]]
 +
 
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 77: Line 79:
  
 
===STEP 5===
 
===STEP 5===
Rebuild Parametric Tube from Collected<td>
+
* Rebuild Parametric Tube from Collected if manual collection was used<td>
[[image:Vtube-STEP_v3.2chstemplate.png|600px]]
+
[[image:Vtube-STEP_v4rebuild.png|600px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 87: Line 89:
 
The XYZ and LRA grid will now have parametric data in them. This information can be sent to a bender, or brought into VTube-LASER to be measured against.</td>
 
The XYZ and LRA grid will now have parametric data in them. This information can be sent to a bender, or brought into VTube-LASER to be measured against.</td>
 
<td>
 
<td>
[[image:vtube-v3.2_exportchs.png|600px]]
+
[[image:vtube-v4parametric.png|600px]]
 
</td>
 
</td>
 
</tr>
 
</tr>
Line 94: Line 96:
 
<td width=300>
 
<td width=300>
  
===STEP 7===
 
Save the .CHS file to the same thumb drive, remove it and take it back to the bender</td>
 
<td>
 
[[image:vtube_v3.2_ATTUSB.png|300px]]
 
</td>
 
</tr>
 
 
<tr>
 
<td width=300>
 
 
===STEP 8===
 
Load the file in the bender and bend the part. Make sure to double check the data in VTube-STEP matches the data in the bender. </td>
 
<td>
 
[[image:vtube_v2.2_chiyodacontrol.png|150px]]
 
</td>
 
</tr>
 
 
</table>
 
<br>
 
  
 
==Other Pages==
 
==Other Pages==
  
 
*Back to the [[VTube-STEP]] page
 
*Back to the [[VTube-STEP]] page

Latest revision as of 19:33, 17 February 2023

Vtube-step logo 1.96.png


This document shows the process of importing a STEP file into VTube-STEP

The files used are .stp files.

Steps to import a .stp file into VTube-STEP

STEP 1

Make sure VTube-STEP is cleared.

Vtube-v4 CLEARED.png

STEP 2

Under Import/Export, import a STEP File-STP.

Vtube-v4 import.png

STEP 3

Load the desired part into VTube-STEP from the file it is saved in inside file explorer

Vtube v4demo6.png

STEP 4

To collect parametric data, an operator can either autobuild or manually collect features.

For Autobuild.

For Manual Collection

Vtube v4autobuild.png

Vtube v4manual.png


STEP 5

  • Rebuild Parametric Tube from Collected if manual collection was used

Vtube-STEP v4rebuild.png

STEP 6

The XYZ and LRA grid will now have parametric data in them. This information can be sent to a bender, or brought into VTube-LASER to be measured against.

Vtube-v4parametric.png


Other Pages