Difference between revisions of "Modicon Momentum"
(→Back of Modicon Momentum I/O Base) |
(→Modicon Momentum Analog Base) |
||
Line 64: | Line 64: | ||
We use an Analog base to output up to 4 separate channels of +/- 10 volts. | We use an Analog base to output up to 4 separate channels of +/- 10 volts. | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
<br> | <br> | ||
[[image:modicaonmomentum_analog.jpg|300px]] | [[image:modicaonmomentum_analog.jpg|300px]] | ||
− | + | <br> | |
+ | <br> | ||
+ | Download a datasheet that describes the Analog cards used:<br> | ||
+ | [http://www.advancedtubular.com/cncbender/170AAO12000_4_channel_analog_output.pdf 0 to 20ma +/-10volt Analog Base]<br> | ||
+ | [http://www.advancedtubular.com/cncbender/170AAO92100_4_channel_analog_output.pdf 4 to 20ma +/-10volt Analog Base] | ||
+ | <br> | ||
+ | Either base can be used depending on availability. | ||
<br> | <br> | ||
Revision as of 20:55, 6 May 2010
Contents |
About the Modicon Momemtum Package
This the form of the modules that are installed to machines that use our CNC Bender software. The different modules come in a variety of functions - but the same packaging. For example, the image here shows an INPUT base with 32-points with an Ethernet Communications Adapter clipped on the top. See this data sheet (16 pages) for an overview of these modules. View the Modicon Momentum I/O Base User Guide (662 pages). They mount to DIN rails in electrical panels. |
I2T IFC220E Servo Modules
The I2T (Pronounced "I Square T") servo modules use the same package form as the other Modicon products. The base unit contains a computer that can control 2 axes.
This is the form for the I2T servo modules with an Ethernet Communications Adapter on the top. You can see a slight difference on the base from the INPUT module with the RJ-45 receptacle. |
|
In the I2T servo modules, the serial port is an RJ-45 receptacle port shown in this image. INPUT and OUTPUT modules don't include this port. |
INPUT Base with Ethernet Communication Adapter
The Ethernet Communications Adapter holds the IP address for this base, and receives the Ethernet cable from a switch or a hub. Each bender is its own small Class C network with addresses like 192.168.0.201, 192.168.0.202, etc.
Back of Modicon Momentum I/O Base
This is the back of the base with a channel for receiving a DIN rail.
Modicon Momentum Analog Base
We use an Analog base to output up to 4 separate channels of +/- 10 volts.
Download a datasheet that describes the Analog cards used:
0 to 20ma +/-10volt Analog Base
4 to 20ma +/-10volt Analog Base
Either base can be used depending on availability.
Electrical Panel
Most modules are installed in any order convenient in an electrical panel as shown in this example:
This shows a close-up image of INPUT and OUTPUT modules next to each other in the electrical panel.
Other Pages
- Back to CNC Bender page
- Back to CNC Bender General Information page
- Back to CNC Bender Technical Notes page