Difference between revisions of "VTube-LASER v1.65"

From ATTWiki
Jump to: navigation, search
(25px ENHANCED: Measure Setup - Scan Rate Grid)
(25px Other Changes)
Line 127: Line 127:
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>
<td width=200>
+
<td width=400>
 
* The MOVE command was repaired from the previous version so that it works properly.
 
* The MOVE command was repaired from the previous version so that it works properly.
 
* The System Options menu allows you to browse directly into support folders from inside VTube-LASER.
 
* The System Options menu allows you to browse directly into support folders from inside VTube-LASER.

Revision as of 07:45, 19 May 2011

Vtube-laser logo.jpg

Revision 1.65

Back to VTube-LASER

Vtube-laser 1 63.jpg


Check.jpg NEW: Radius Correction for Push-Bending

Vtube-laser 1 65 radiuscorrection.jpg

The radius correction menu allows VTube-LASER to correct push-bends on Unison Limited benders.

The menu will send data directly to any bender that can read our radius transfer files. The menu can be accessed from the Radius Stripe Scan menu.

Vtube-laser 1 65 radiusstripescan sendradius.jpg



Check.jpg NEW: Bender Setup Changes

Vtube-laser 1 65 benderdata.jpg

The Bender Setup window has a new easier-to-view color scheme.

The bend setup grid has a new column for inverting rotations that are sent out to the bender. This allows for sending the rotation the opposite direction - then remembering the inversion for next time the project is run.

Vtube-laser 1 65 invertrotations.jpg



Check.jpg ENHANCED: New Torus-fit engine for Radius Stripe Scanning

The new radius stripe scanning method is more accurate as of this version of VTube due to a new torus-fit engine included in VTube.

Vtube-laser 1 65 radiusstripescan.jpg

Vtube-laser radius stripe scanning.jpg



Check.jpg NEW: Bender Data + Corrections Data Chart in Reports

A new bender chart was added to the report template to include the bender data + corrections chart

Vtube-laser 1 65 benderpluscorrections.jpg




Check.jpg ENHANCED: Report Preview Menu

The Report Preview menu now allows you to change the printer and the paper orientation before printing.

Vtube-laser 1 65 reportpreview.jpg




Check.jpg ENHANCED: Measure Setup - Laser Probe Grid

The Laser probe grid now has a separate checkbox for automatically enabling either laser or tactile measuring for radius stripe scans.

Vtube-laser 1 65 radiusstripescansuselaser.jpg




Check.jpg ENHANCED: Measure Setup - Scan Rate Grid

The Scan Rate grid now has a separate controls for radius stripe scans.

Vtube-laser 1 65 radiusstripescansscansrate.jpg




Check.jpg Other Changes

  • The MOVE command was repaired from the previous version so that it works properly.
  • The System Options menu allows you to browse directly into support folders from inside VTube-LASER.
  • VTube-LASER now uses the "All Users" or "ProgramData" folders to store configuration data for all users of the FARO computer.
  • The Winton Machinery bender protocol was enhanced so that it automatically loads a template if no data is present in memory.



Check.jpg Issues with this version fixed in newer versions

  • No known issues



Other Pages

VTube-LASER Training Video - How to perform effective end scans.

Vtube-laser effective end scan video b.jpg