* Aim the laser at the target so that it strikes the target as perpendicular to the surface as possible. Avoid returning any points other than the target.<br><br> | * Aim the laser at the target so that it strikes the target as perpendicular to the surface as possible. Avoid returning any points other than the target.<br><br> | ||
− | * Attempt to hold the laser motionless when collecting the stripes across the target to increase repeatability. | + | * Attempt to hold the laser motionless when collecting the stripes across the target to increase repeatability.<br><br> |
* Consistently place the line across the same area of the target from measure to measure. | * Consistently place the line across the same area of the target from measure to measure. | ||
</td> | </td> |
Revision as of 03:40, 1 February 2012
How to perform super high accuracy end-scans using an end target.
|
Why the End-Scan technique is important
The quick End-Scan Using the Scissor Motion technique is not always precisely repeatable if you use any of the AUTO exposure settings to set the LASER exposure in real-time. The reason is that as he laser drops off the end of the tube, the automatic exposure feature impacts which of the points are kept where the tube drops off (at the end).
|
Measure Setup
|
Apply the Target
|
Measure the Target
When it is time to perform and end-scan, use the following technique to scan the target:
|
Approve the Measurement On the Screen
|
Using End Target Adapters
|