<pre>[Axis 1]</pre>
 
<pre>[Axis 1]</pre>
 +
 +
Each section has individual properties that pertain to that axis.
  
  
Line 14: Line 16:
 
[[Delay After Cycle Start]]
 
[[Delay After Cycle Start]]
  
 
+
Example properties for an axis:
 +
<pre>
 +
Type=Feed
 +
Module Name=servo_controller_module_1
 +
Module Axis=1
 +
Position Multiplier For Display= 1.0
 +
Position Rollover= 32000
 +
Position Rollover Tolerance= 10
 +
// Move Feed Axis forward 0.25 forward and make that ZERO
 +
// This prevents ever getting into slight negative region
 +
// which causes rollover problems.
 +
Position Offset=0.25
 +
Position Offset Speed=400
 +
Datum Offset=0
 +
Home Required=1
 +
Monitor Fault State=1
 +
Monitor Enable State=1
 +
Monitor In-Position State=1
 +
// 1 = -10 to +10 volts
 +
Analog Clamp Voltage Setup=1
 +
Digital To Analog Datum=8191
 +
Is Linear = 1
 +
Delay After Cycle Start = 250
 +
</pre>
  
 
--[[User:Mcone|Mcone]] 10:37, 17 July 2006 (EDT)
 
--[[User:Mcone|Mcone]] 10:37, 17 July 2006 (EDT)

Revision as of 14:48, 17 July 2006

Contents


What is It?

The main.axislist file exists in the c:\cnc\config\axis folder. It contains setup information for each of the controlled axes on a CNC bender.

Sections

Each of the sections in the main.axislist is set apart with an axis section label like this:

[Axis 1]

Each section has individual properties that pertain to that axis.


Properties

As of 10.0.5.9:
Delay After Cycle Start

Example properties for an axis:

Type=Feed
Module Name=servo_controller_module_1
Module Axis=1
Position Multiplier For Display= 1.0
Position Rollover= 32000
Position Rollover Tolerance= 10
// Move Feed Axis forward 0.25 forward and make that ZERO
// This prevents ever getting into slight negative region
// which causes rollover problems.
Position Offset=0.25
Position Offset Speed=400
Datum Offset=0
Home Required=1
Monitor Fault State=1
Monitor Enable State=1
Monitor In-Position State=1
// 1 = -10 to +10 volts
Analog Clamp Voltage Setup=1
Digital To Analog Datum=8191
Is Linear = 1
Delay After Cycle Start = 250