Difference between revisions of "Cable Spec 33"
From ATTWiki
(→CB-EL1 Board Setup For Use With Cable 33) |
|||
Line 15: | Line 15: | ||
==CB-EL1 Board Setup For Use With Cable 33== | ==CB-EL1 Board Setup For Use With Cable 33== | ||
In this configuration, it is necessary to use a version 2 CB-EL1 board with the jumpers set to "BND" to simulate the bender side of the connection. Use this setup for connecting a non Eaton Leonard bender to an Eaton Leonard Vector measuring center.<br><br> | In this configuration, it is necessary to use a version 2 CB-EL1 board with the jumpers set to "BND" to simulate the bender side of the connection. Use this setup for connecting a non Eaton Leonard bender to an Eaton Leonard Vector measuring center.<br><br> | ||
− | The original CB-EL1 board | + | The original CB-EL1 board (without jumpers) can only handle the Vector measuring center side connection. Do not use v1 in this configuration.<br><br> |
− | [[image:cb-el1_bendermode.jpg|800px]] | + | [[image:cb-el1_bendermode.jpg|800px]] |
− | + | ||
− | + | ||
==Other Pages== | ==Other Pages== | ||
*[[Cable Spec]]s | *[[Cable Spec]]s |
Revision as of 21:00, 17 September 2012
For use inside Benderlink Ethernet Modules with current loop electronics.
Use for simulating the PREMIER (Bender) side only.
Wiring schematic:
CB-EL1 Board Setup For Use With Cable 33
In this configuration, it is necessary to use a version 2 CB-EL1 board with the jumpers set to "BND" to simulate the bender side of the connection. Use this setup for connecting a non Eaton Leonard bender to an Eaton Leonard Vector measuring center.
The original CB-EL1 board (without jumpers) can only handle the Vector measuring center side connection. Do not use v1 in this configuration.