Difference between revisions of "VTube-LASER v1.82.1"
From ATTWiki
(Blanked the page) |
|||
Line 1: | Line 1: | ||
+ | <table> | ||
+ | <tr cellpadding=10> | ||
+ | <td width=225> | ||
+ | [[image:vtube-laser_logo.jpg|300px]] | ||
+ | ==Revision 1.82.1== | ||
+ | * Back to [[VTube-STEP]] | ||
+ | * Back to [[VTube Software Updates]] (for LASER Mode) | ||
+ | * Back to [[VTube-LASER]] | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-laser_1.81.4.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | __NOTOC__ | ||
+ | |||
+ | * See [http://www.advancedtubular.com/customers/vtube VTube-LASER Customer Support Page] to download the latest version. | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCEMENTS: User Interface Changes=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | The user interface can adjust the font sizes to fit more data on the screen. | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCEMENT: Track the Last Adjustment Calc Time=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | It is useful to know when the last adjustment calculation was performed - to be sure that the data in the Bender Setup menu is the latest data. | ||
+ | <br><br> | ||
+ | Bender Setup now displays the time of the most recent adjusment calculation to help you know that you are working with the correct adjustment data.<br><br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Intersection Point Inspection Grid=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | VTube has a new XYZ intersection point inspection grid in the Inspection menu.<br><br> | ||
+ | |||
+ | The grid is wider than the panel that is displayed on. Use the horizontal scroll bar to view the entire grid. This is a sample of the left side of the grid:<br> | ||
+ | [[image:vtube-1.82_xyzintersection_inspection_grid.jpg|400px]] | ||
+ | <br><br> | ||
+ | This is a sample of the right side of the grid:<br> | ||
+ | [[image:vtube-1.82_xyzintersection_inspection_grid_3d.jpg|400px]] | ||
+ | |||
+ | |||
+ | <br> | ||
+ | |||
+ | |||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-1.82_xyzintersection_inspection_grid_entire_screen.jpg|300px]]<br><br> | ||
+ | [[image:vtube-1.82_xyzintersection_inspection_grid_whole_menu.jpg|300px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] ENHANCEMENTS: Bender Setup Adjustments and Menu Changes === | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | These two changes are made to bender corrections:<br><br> | ||
+ | |||
+ | ====Better Adjustment Calculation Handling==== | ||
+ | |||
+ | * Previous versions would always recalculate the LRA adjustment values when loading the Bender Setup menu. This was problem because the LRA adjustment values could never be manually adjusted or cleared by the user. Now the adjustment values are calculated only when a new measured tube is created.<br><br> | ||
+ | * The adjustment values in the Bender Setup screen are now stored in the project files. This means that the values will be retained between sessions. You can clear the adjustments, and they will stay zeroed until a new measured tube is created. | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ====New "Copy Master Part Setup Values" Button==== | ||
+ | |||
+ | This button allows you to update just the part setup values in Bender Setup without changing the LRA bender data. | ||
+ | |||
+ | [[image:vtube-1.82_bendersetup_copymasterpartsetup.jpg|400px]] | ||
+ | <br><br> | ||
+ | |||
+ | |||
+ | <br> | ||
+ | |||
+ | |||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-1.82_bendersetup.jpg|300px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | ===[[image:Check.jpg|25px]] NEW: Updated Viewport Background Interface=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | |||
+ | The new interface uses a blue gradient background for a better viewing experience.<br><br> | ||
+ | [[image:vtube-1.82_screen_viewport.jpg|500px]] | ||
+ | |||
+ | </td> | ||
+ | <td width=300> | ||
+ | [[image:vtube-1.82_screen.jpg|300px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | <br><br> | ||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] Other Changes=== | ||
+ | <table cellpadding=10> | ||
+ | <tr valign=top> | ||
+ | <td width=400> | ||
+ | |||
+ | * Overbend Calculator is now integrated into VTube. The values are now always updated and transferred back to VTube as they are entered in the Overbend.<br><br> | ||
+ | * Fixed default radius bug for single straight tubes.<br><br> | ||
+ | * Repaired the End Label delete when tube is cleared. (The End Labels did not always clear from the screen when the tubes were cleared or turned off.)<br><br> | ||
+ | </td> | ||
+ | <td width=300> | ||
+ | |||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ==Other== | ||
+ | * Back to [[VTube-STEP]] | ||
+ | * Back to [[VTube Software Updates]] (for LASER Mode) | ||
+ | * Back to [[VTube-LASER]] | ||
+ | * See [[VTube Language Editor]] |
Revision as of 21:42, 29 June 2013
Revision 1.82.1
|
- See VTube-LASER Customer Support Page to download the latest version.
ENHANCEMENTS: User Interface Changes
The user interface can adjust the font sizes to fit more data on the screen. |
ENHANCEMENT: Track the Last Adjustment Calc Time
It is useful to know when the last adjustment calculation was performed - to be sure that the data in the Bender Setup menu is the latest data.
|
NEW: Intersection Point Inspection Grid
ENHANCEMENTS: Bender Setup Adjustments and Menu Changes
These two changes are made to bender corrections: Better Adjustment Calculation Handling
New "Copy Master Part Setup Values" ButtonThis button allows you to update just the part setup values in Bender Setup without changing the LRA bender data.
|
NEW: Updated Viewport Background Interface
The new interface uses a blue gradient background for a better viewing experience. |
Other Changes
|
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor