Some AddisonMckee Mark IV benders require that its custom teach mode data be returned in the communication data during an automated bender correction from VTube. For benders that require this data during corrections from VTube, if this data is not found by the control, then a small message box will appear with a message that the incoming data is not AddisonMckee Mark IV data, and the correction data will be ignored.<br><br> | Some AddisonMckee Mark IV benders require that its custom teach mode data be returned in the communication data during an automated bender correction from VTube. For benders that require this data during corrections from VTube, if this data is not found by the control, then a small message box will appear with a message that the incoming data is not AddisonMckee Mark IV data, and the correction data will be ignored.<br><br> | ||
− | To solve this problem, VTube-LASER now | + | To solve this problem, VTube-LASER now takes in and stores this data during a RECALL from the bender. This means that a RECALL is required before corrections are made to this kind of control.<br><br> |
* If the Mark IV data is available, then a new tab menu appears next to the correction grid in Bender Data Setup.<br><br> | * If the Mark IV data is available, then a new tab menu appears next to the correction grid in Bender Data Setup.<br><br> |
Revision as of 14:39, 20 January 2014
Revision 1.86
|
Contents |
- See VTube-LASER Customer Support Page to download the latest version.
ENHANCED: Bender Number Stored in Project
The bender number selected for communications is now stored in the project file for recall later. The assumption is that a given part is often bent on the same bender.
|
ENHANCED: AddisonMckee Mark IV EXTENDED Communications
Some AddisonMckee Mark IV benders require that its custom teach mode data be returned in the communication data during an automated bender correction from VTube. For benders that require this data during corrections from VTube, if this data is not found by the control, then a small message box will appear with a message that the incoming data is not AddisonMckee Mark IV data, and the correction data will be ignored. To solve this problem, VTube-LASER now takes in and stores this data during a RECALL from the bender. This means that a RECALL is required before corrections are made to this kind of control.
|
Other Changes
|