Difference between revisions of "VTube-LASER v1.91"
(→FEATURE 1 - ALIGNMENT ENGINE: Fixes and Significantly More Powerful) |
(→FEATURE 1 - ALIGNMENT ENGINE: Fixes and Significantly More Powerful) |
||
Line 116: | Line 116: | ||
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
+ | |||
<td width=400> | <td width=400> | ||
The automatic end weighting Best Fit alignment method is significantly improved:<br><br> | The automatic end weighting Best Fit alignment method is significantly improved:<br><br> | ||
− | |||
− | |||
− | |||
− | < | + | <table> |
+ | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
+ | =====Real Time Deviations===== | ||
+ | Each iteration of the deviations are shown in real time in the Inspection Data menu. Watch the grids change rapidly as the engine tries new alignments. | ||
+ | </td> | ||
+ | <td> | ||
[[image:vtube-laser-1.91-realtime_deviations.png|300px]]<br><br> | [[image:vtube-laser-1.91-realtime_deviations.png|300px]]<br><br> | ||
+ | </td> | ||
+ | </table> | ||
+ | |||
+ | <table> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | =====Goal Precision===== | ||
+ | The progress window shows the goal precision level the engine is seeking for. For example, if the Automatic Alignment Stop value is 0.75 and the tolerance is 0.059, then the progress window will show "Alignment Engine seeking precision level of: 0.044". The goal precision is used in decision making during automatic alignments. If all tangent deviations are equal to or less than the goal precision, then '''alignment stops immediately'''. This makes automatic alignment much faster potentially.<br><br> | ||
+ | </td> | ||
+ | <td> | ||
[[image:vtube-laser-1.91-goalprecision_display.png|300px]]<br><br> | [[image:vtube-laser-1.91-goalprecision_display.png|300px]]<br><br> | ||
+ | </td> | ||
+ | </table> | ||
+ | |||
+ | <table> | ||
+ | <tr valign=top> | ||
+ | <td width=300> | ||
+ | ===== New Value Name for Clarity===== | ||
+ | The '''Automatic Alignment Stop''' value is renamed to make it more understandable: "Automatic Alignment Stop at Deviation Multiplied Against..." is the new name. | ||
+ | </td> | ||
+ | <td> | ||
[[image:vtube-laser-1.91-alignment_stop_caption.png|300px]]<br><br> | [[image:vtube-laser-1.91-alignment_stop_caption.png|300px]]<br><br> | ||
+ | </td> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | </td> | ||
+ | <td width=300> | ||
+ | |||
+ | |||
</td> | </td> | ||
</tr> | </tr> |
Revision as of 15:57, 28 June 2014
Revision 1.91
|
- See VTube-LASER Customer Support Page to download the latest version.
NEW: Use Leapfrog To Measure Tubes Longer Than the Arm's Reach
NEW: Redesign for XYZ INTERSECTION Inspection Values
The data shown on the right is from the new Expanded Grid (see "Expanded Grid" section below). |
NEW: Redesign for XYZ TANGENT Inspection Values
The data shown on the right is from the new Expanded Grid (see "Expanded Grid" section below). |
NEW: Expanded Grid Window for Inspection Data, Send to MS Office
The XYZ Intersection deviation and the XYZ Tangent point deviation values can now be displayed in the Expanded Grid window.
|
NEW: XYZ Intersection +/- Tolerance Values in Printed Reports
The new XYZ Intersection deviation values are included in reports:
|
ENHANCED and NEW: Alignment Feature Changes
FEATURE 1 - ALIGNMENT ENGINE: Fixes and Significantly More Powerful
The automatic end weighting Best Fit alignment method is significantly improved:
FEATURE 2 - MEASURE COMPLETE WINDOW: Measurement Complete Dialog REDESIGNED with Alignment Choices
FEATURE 2 - INSPECTION DATA MENU: Alignment Button Displays Alignment Method Selected
NEW: Direct Communications with Eaton Leonard Premier, EL2000, and Ve-log Benders
Enhanced: Project Batch Report OutputOther Changes
Other
|