Difference between revisions of "VTube-LASER v1.91"
(→FEATURE 2 - INSPECTION DATA MENU: Alignment Button Displays Alignment Method Selected) |
(→Alignment Engine Seeking Precision Level Display) |
||
Line 131: | Line 131: | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
− | =====Alignment Engine Seeking Precision Level Display===== | + | =====Alignment Engine "Seeking Precision Level" Display===== |
The progress window shows the goal precision level the engine is seeking for. For example, if the Automatic Alignment Stop value is 0.75 and the tolerance is 0.059, then the progress window will show "Alignment Engine seeking precision level of: 0.044". The goal precision is used in decision making during automatic alignments. If all tangent deviations are equal to or less than the goal precision, then '''alignment stops immediately'''. This makes automatic alignment much faster potentially.<br><br> | The progress window shows the goal precision level the engine is seeking for. For example, if the Automatic Alignment Stop value is 0.75 and the tolerance is 0.059, then the progress window will show "Alignment Engine seeking precision level of: 0.044". The goal precision is used in decision making during automatic alignments. If all tangent deviations are equal to or less than the goal precision, then '''alignment stops immediately'''. This makes automatic alignment much faster potentially.<br><br> | ||
+ | </td> | ||
+ | <td> | ||
+ | [[image:vtube-laser-1.91-goalprecision_display.png|300px]]<br><br> | ||
+ | </td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | =====Alignment Engine "Possible Iterations" Display===== | ||
+ | The current iteration and possible iterations for finding the best alignment is now displayed in the progress window.<br><br> | ||
+ | * The "possible iterations" is the number of alignments that VTube has found that may want to compare.<br><br> | ||
+ | * If 100 iterations passes with no ''improvement'' to the '''Average Tangent Deviation" and the '''Highest Tangent Deviation''' values, then '''alignment stops immediately''' to save time.<br><br> | ||
</td> | </td> | ||
<td> | <td> |
Revision as of 16:10, 28 June 2014
Revision 1.91
|
- See VTube-LASER Customer Support Page to download the latest version.
NEW: Use Leapfrog To Measure Tubes Longer Than the Arm's Reach
NEW: Redesign for XYZ INTERSECTION Inspection Values
The data shown on the right is from the new Expanded Grid (see "Expanded Grid" section below). |
NEW: Redesign for XYZ TANGENT Inspection Values
The data shown on the right is from the new Expanded Grid (see "Expanded Grid" section below). |
NEW: Expanded Grid Window for Inspection Data, Send to MS Office
The XYZ Intersection deviation and the XYZ Tangent point deviation values can now be displayed in the Expanded Grid window.
|
NEW: XYZ Intersection +/- Tolerance Values in Printed Reports
The new XYZ Intersection deviation values are included in reports:
|
ENHANCED and NEW: Alignment Feature Changes
FEATURE 1 - ALIGNMENT ENGINE: Fixes and Significantly More Powerful
The automatic end weighting Best Fit alignment method is significantly improved: Real Time DeviationsEach iteration of the deviations are shown in real time in the Inspection Data menu. Watch the grids change rapidly as the engine tries new alignments. |
Alignment Engine "Seeking Precision Level" DisplayThe progress window shows the goal precision level the engine is seeking for. For example, if the Automatic Alignment Stop value is 0.75 and the tolerance is 0.059, then the progress window will show "Alignment Engine seeking precision level of: 0.044". The goal precision is used in decision making during automatic alignments. If all tangent deviations are equal to or less than the goal precision, then alignment stops immediately. This makes automatic alignment much faster potentially. |
Alignment Engine "Possible Iterations" Display
The current iteration and possible iterations for finding the best alignment is now displayed in the progress window.
- The "possible iterations" is the number of alignments that VTube has found that may want to compare.
- If 100 iterations passes with no improvement to the Average Tangent Deviation" and the Highest Tangent Deviation values, then alignment stops immediately to save time.
</td>
<td>
</td>
</tr>
</table>
FEATURE 2 - MEASURE COMPLETE WINDOW: Measurement Complete Dialog REDESIGNED with Alignment Choices
This new measurement complete dialog gives you more choices than before. It no longer assumes that you want to use the current default alignment method. |
FEATURE 3 - INSPECTION DATA MENU: Alignment Button Displays Alignment Method Selected
The Inspection Data recalculate alignment button now displays the currently selected alignment method. This fixes a problem where users had to guess the alignment method when recalculating the measured to master alignment. |
FEATURE 4 - ALIGNMENT MENU: Value RENAMED for Clarity
The Automatic Alignment Stop value in the Inspection Data / Alignment menu is renamed to make it more understandable: "Automatic Alignment Stop at Deviation Multiplied Against..." is the new name. |
NEW: Direct Communications with Eaton Leonard Premier, EL2000, and Ve-log Benders
|
Enhanced: Project Batch Report Output
Other Changes
|
Other
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER
- See VTube Language Editor