==[[image:Check.jpg|25px]] ENHANCED: No Longer Clear Tool with Tube==
+
==[[image:Check.jpg|25px]] ENHANCED: No Longer Clear Tool Data Page with TubeShape Clear==
  
 
<table>
 
<table>
Line 22: Line 22:
 
<td width=400>
 
<td width=400>
  
<h4><b>If you have a hand-bender controlled by CNC Bender and you use custom commands for the ROTATE axis, then this upgrade is important to you.</b></h4>
+
Previous versions of CNC Bender would clear the Tool page when the TubeShape page was clearedThis creates a problem in workflow, because the tool data is setup before the part is setupClearing the TubeShape page should never clear the tool page.<br><br>
 
+
This issue has been resolved in this version.
Custom commands can be entered after every bend in the FRB page.  SMT discovered a that FEED and ROTATE commands would not be completed properly when coming out of a custom move.<br><br>
+
* For example, the ROTATE was programmed at 90 degrees.  The custom move is 89 degrees - so the finish up command should be set to 1 degree to come to the full 90However, the finish-up command was 90 degrees - which caused the rotate to move to 89 + 90 = 179 degrees.<br><br>
+
* This problem occurred on benders where the ROTATE axis is set to a non-standard machine axis 3 because the machine axis number "2" was hard coded into the process list builder.<br><br>
+
* Process list builder now has logic that anticipates that the machine axis number for any motion actuator can change depending on the application.
+
 
+
 
<td>
 
<td>
[[image:smt_handbender.png|400px]]
+
[[image:cnc_v12.11_toolpage_tubeshape_notclear.png|400px]]
 
</td>
 
</td>
 
</tr>
 
</tr>

Revision as of 14:59, 16 July 2014

v12.11 - July 16, 2014

Cncv12procontrol withteachmode.jpg


Check.jpg ENHANCED: No Longer Clear Tool Data Page with TubeShape Clear

Previous versions of CNC Bender would clear the Tool page when the TubeShape page was cleared. This creates a problem in workflow, because the tool data is setup before the part is setup. Clearing the TubeShape page should never clear the tool page.

This issue has been resolved in this version.

400px





Check.jpg ENHANCED: Load and Start Positions with Bend Arm Motion Option (in Pre Bend)

The Option List panels now clear if all options are placed in the tool box.

Cncbender OptionPanelCleared.png



Check.jpg Other Changes