Difference between revisions of "VTube-STEP v1.94"
(→25px ENHANCED: Automatic Projection Tolerance for Centerline Calculation) |
(→25px ENHANCED: Automatic Projection Tolerance for Centerline Calculation) |
||
Line 78: | Line 78: | ||
</table> | </table> | ||
− | ===[[image:Check.jpg|25px]] ENHANCED: | + | ===[[image:Check.jpg|25px]] ENHANCED: DEFAULT Projection Tolerance for Centerline Calculation is Removed from Interface === |
<table cellpadding=10> | <table cellpadding=10> | ||
Line 90: | Line 90: | ||
</td> | </td> | ||
</tr> | </tr> | ||
+ | </table> | ||
+ | |||
+ | |||
+ | |||
+ | ===[[image:Check.jpg|25px]] CRITICAL ENHANCEMENT: Cylinder Centerline Calculation in Math Engine Improved for Very Rough Cylinders === | ||
+ | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=300> | <td width=300> | ||
'''PROJECTION TOLERANCE ACCURACY'''<br><br> | '''PROJECTION TOLERANCE ACCURACY'''<br><br> | ||
− | + | To enhance the calculations, the automatic Projection Tolerance in VTube-STEP now starts with an much smaller projection tolerance at a 10th of a micron (0.0001 mm, or 0.000003937 inches).<br><br> | |
If the centerline for the cylinders cannot be solved for, then VTube increases the projection tolerance until it finds a solution.<br><br> | If the centerline for the cylinders cannot be solved for, then VTube increases the projection tolerance until it finds a solution.<br><br> | ||
The final projection tolerance used is stored in the Collection grid so that you can view the result at any time after a calculation. | The final projection tolerance used is stored in the Collection grid so that you can view the result at any time after a calculation. |
Revision as of 17:20, 29 August 2014
Revision 1.94
|
- See VTube-STEP Customer Support Page to download the latest version.
NEW: Trim Surface Datum for Trimming or Extending End Lengths
VTube-STEP now allows for different kind of Trim Surfaces now. Older versions only allow for the centroid (average XYZ point) of all points in a solid used to trim. |
|
|
|
|
|
|
NEW: Add Collection Grid Properties Column and Edit Datum Menu
ENHANCED: DEFAULT Projection Tolerance for Centerline Calculation is Removed from Interface
Since the STEP mode calculation engine completely automates the Projection Tolerance, there is no longer a need for the user to set this value. |
CRITICAL ENHANCEMENT: Cylinder Centerline Calculation in Math Engine Improved for Very Rough Cylinders
PROJECTION TOLERANCE ACCURACY |
Other Changes
|
Other Pages
- Back to VTube-STEP
- Back to VTube Software Updates (for LASER Mode)
- Back to VTube-LASER