Difference between revisions of "Setup VTube for Supravision Network Communication"

From ATTWiki
Jump to: navigation, search
(VTube-STEP Setup for Supravision Network Communications)
(Setup SolidWorks with Default Templates)
Line 29: Line 29:
 
* At the bender control, set the protocol to Supravision Network, set the bender number, set the path, and turn on communications if this is required.
 
* At the bender control, set the protocol to Supravision Network, set the bender number, set the path, and turn on communications if this is required.
  
==Setup SolidWorks with Default Templates==
+
==VTube-LASER Setup for Supravision Network Communications==
  
The solution is to setup the Default TEMPLATE path in Tools / Options following these steps.<br>
+
VTube-LASER uses a Benderlink grid to setup the communications protocol for each bender.  The grid is in Setup Options, Measure 2, Setup Benderlink Options menu.<br>
  
 
===Step 1:  Move the mouse over the menu arrow to the right of the SolidWorks logo in the upper right corner.===
 
===Step 1:  Move the mouse over the menu arrow to the right of the SolidWorks logo in the upper right corner.===

Revision as of 03:40, 9 January 2015

Vtube-laser logo 1.96.png Vtube-step logo 1.96.png



VTube-LASER and VTube-STEP can communicate with bender controls using the Supravision Network protocol.

VTube-STEP can SEND data to benders using the protocol. VTube-LASER can SEND and RECALL data to/from benders for full corrections loops.

Follow this guide to setup the VTube for communications with benders using the Supravision Network protocol.

Vtube 1.99 BendPro Connection.png


VTube-STEP Setup for Supravision Network Communications

Use the VTube-STEP Bender Output menu to setup and send new part data to a bender using Supravision Network protocol:

Vtube-step 1.99 supravision network.png



Go to the SV Network tab and choose the bender number and set the shared path where Supravision Network communications occurs.

  • The Supravision Network protocol uses a bender number (from 1 to 99) to indicate which bender should pickup and use the Supravision file that is being saved by VTube-STEP to the file path in the network box.

  • At the bender control, set the protocol to Supravision Network, set the bender number, set the path, and turn on communications if this is required.

VTube-LASER Setup for Supravision Network Communications

VTube-LASER uses a Benderlink grid to setup the communications protocol for each bender. The grid is in Setup Options, Measure 2, Setup Benderlink Options menu.

Step 1: Move the mouse over the menu arrow to the right of the SolidWorks logo in the upper right corner.

SolidWorks Toolbar.png

Step 2: Move the mouse to Tools and down to Options - Click on Options

SolidWorks ToolsOptions Menu.png

Step 3: Click on Default Templates in the left column

SolidWorks ToolsOptions DefaultTemplatePaths Empty.png

Step 4: Choose the template files

Click on the ellipses buttons to setup the default path in these boxes. SolidWorks will suggest a file that already exists on the disk. Click on that file.

Fill in all three boxes with filenames.

SolidWorks ToolsOptions DefaultTemplatePaths.png

Click on OK. SolidWorks is ready to receive VTube commands.