There are two ways to overcome the opposite correction problem: | There are two ways to overcome the opposite correction problem: | ||
− | 1 - Use a special INVERSION checkbox in the Supravision Export menu. Only use this inversion switch when sending measured data for correction.<br><br> | + | 1 - Use a special INVERSION checkbox in the VTube Supravision Export menu. Only use this inversion switch when sending measured data for correction.<br><br> |
2 - Have the YLM technician change the internal low level setting in the YLM control that applies the correction in the normal direction.<br><br> | 2 - Have the YLM technician change the internal low level setting in the YLM control that applies the correction in the normal direction.<br><br> |
Revision as of 19:35, 24 June 2015
Read about YLM benders here.
VTube-STEP and VTube-LASER Support for YLM Benders
VTube-STEP can export Supravision data to YLM benders. |
Using VTube-LASER to send NEW MASTER Data to YLM Benders
The connection the bender is made with standard network connection, and a shared folder location between the VTube computer and the operator station computer. For a NEW TUBE, the YLM takes in VTube MASTER Supravision LRA data in a Supravision file.
|
Follow these steps at VTube-LASER to Send a NEW TUBE SETUP to a YLM Bender
STEP 1 |
Follow these steps at the YLM CONTROL to import the MASTER data from VTube-LASER
STEP 1 |
|
STEP 2 |
|
STEP 3 |
|
STEP 4 |
|
STEP 5 |
|
STEP 6 |
VTube-LASER CORRECTION Steps for YLM Benders
The connection the bender is made with standard network connection, and a shared folder location between the VTube computer and the operator station computer.
Handling Opposite CorrectionsThere are two ways to overcome the opposite correction problem: 1 - Use a special INVERSION checkbox in the VTube Supravision Export menu. Only use this inversion switch when sending measured data for correction. 2 - Have the YLM technician change the internal low level setting in the YLM control that applies the correction in the normal direction. |
Follow these steps at VTube-LASER to Correct a YLM Bender
STEP 1 |
|
STEP 2 |
|
STEP 3 |
Follow these steps at the YLM CONTROL to import the measured data from VTube-LASER
STEP 1 |
|
STEP 2 |
|
STEP 4 |
Shutdown to Edit the Windows Setup
To shutdown the YLM software to configure Windows settings:
- Press the Shutdown button.
- Press "NO" for shutdown.
- Type "12345" and OK in the numeric keypad.
- YLM will close without shutting down the computer.