− | + | The Communications Status box in the LightSpeed Vector menu should show activity - like that the incoming file was saved.<br><br>You will also see the options of Overwriting the part data, or Importing the YBC data only. Overwriting the part data will allow the new data to completely overwrite the part in memory. Pressing the YBC data only will change only the YBC data in memory with the incoming data.<br><br> | |
For setting up a new part, you can press overwrite. For corrections you can press YBC data only. In this test, press overwrite the part. | For setting up a new part, you can press overwrite. For corrections you can press YBC data only. In this test, press overwrite the part. | ||
</td> | </td> |
Revision as of 01:45, 13 November 2015
This document outlines the basic communications setup for a Lightspeed control. |
|
|
SVNET Communications Setup Instructions
This is good for use in connecting with our VTube-LASER, VTube-STEP, and Benderlink software packages. All of them are equipped with the Supravision Network protocol. |
STEP 1: System Menu and Administrative Control
Change to the Systems menu. If you are not running the operator station as an administrator, then press SECURITY and enter the administrator code. (The default code is "123".) Press the DEVICE CONFIG button. |
STEP 2: Device Config / Machine Menu
In DEVICE CONFIG, enter the MACHINE menu. Select a Measure Machine tab. LightSpeed can store four simultaneous measuring center setups for connection to multiple measuring centers.
|
Communications Test on the LightSpeed Side
In order to communicate with the LightSpeed control, it's necessary to switch on remote communications in the control in the user interface. |
STEP 1: Enter the Vector Menu
Click on the "Vector" button on the right side of the screen. |
STEP 2: Allow Network Control
In the VECTOR menu, press the "Allow Network Control" button until it turns orange. (Orange indicates that it is toggled on.) |
STEP 3: SEND a Part from the Measuring Center
From the measuring center, send a part to the LightSpeed. (This assumes that the connection has been made and that the SVNET protcol is being used, and that the appropriate bender number is used at the measuring center. |
STEP 4: Observe the LightSpeed Communications Status Box
The Communications Status box in the LightSpeed Vector menu should show activity - like that the incoming file was saved. |