(25px IMPROVED: Best Fit - Automatic End Weight Version 2 - Tighter and Faster Alignments)
(25px IMPROVED: Best Fit - Automatic End Weight Version 2 - Tighter and Faster Alignments)
Line 29: Line 29:
 
The alignments shown on the right are the results of the two different kinds of alignments now available in version 2.5.  We used the same master/measured data.  When qualifications are on the edge of the tolerance, then the new version 2 of Best Fit has a better chance of qualifying a tube.<br><br>
 
The alignments shown on the right are the results of the two different kinds of alignments now available in version 2.5.  We used the same master/measured data.  When qualifications are on the edge of the tolerance, then the new version 2 of Best Fit has a better chance of qualifying a tube.<br><br>
  
Another benefit to version 2 is that it makes the part of the tube that is good to more closely align with the tube.
 
 
   
 
   
 
'''Note: We understand that some customers are very careful when approving new part alignment algorithms - so we were careful to leave the original version Best Fit option in the VTube Inspection Results menu to give you time to learn to trust and use Best Fit version 2.'''
 
'''Note: We understand that some customers are very careful when approving new part alignment algorithms - so we were careful to leave the original version Best Fit option in the VTube Inspection Results menu to give you time to learn to trust and use Best Fit version 2.'''

Revision as of 23:58, 28 March 2016

Vtube-laser logo 1.96.png

Revision 2.5

Vtube-laser 1.89 mainscreen.png

Contents


Check.jpg IMPROVED: Best Fit - Automatic End Weight Version 2 - Tighter and Faster Alignments

We're always happy to give you a feature that does more - and does more FASTER than before. This is one of those features.

Version 2 of the Best Fit engine aligns tube shapes faster and tighter than the original. For example, a 25 second alignment is now made in 20 seconds, and a 0.013" average deviation might drop to an average of 0.009".

Version 1 was very good at tight alignments as the measured tube shape started to conform more to the master tube shape. However, version 2 creates a tighter fit faster - and handles shapes that are further from the master shape much better than version 1.

The alignments shown on the right are the results of the two different kinds of alignments now available in version 2.5. We used the same master/measured data. When qualifications are on the edge of the tolerance, then the new version 2 of Best Fit has a better chance of qualifying a tube.


Note: We understand that some customers are very careful when approving new part alignment algorithms - so we were careful to leave the original version Best Fit option in the VTube Inspection Results menu to give you time to learn to trust and use Best Fit version 2.

Vtube-laser v2.5 bestfit version1.png

Vtube-laser v2.5 bestfit version2.png




Other