− | == | + | ==STEPS TO SEND A NEW PART== |
# Enter the Bender Setup window. Set the bender number (at the top of the window). The protocol should show Eaton Leonard. The bender image show show an Eaton Leonard bender.<br><br> | # Enter the Bender Setup window. Set the bender number (at the top of the window). The protocol should show Eaton Leonard. The bender image show show an Eaton Leonard bender.<br><br> | ||
# If the blue columns only have zeros, or there are no rows in the LRA grid, bring new part data into the Bender Setup window by using the Setup this Window button on the right. Click on "Copy MASTER LRA to Setup LRA". This will bring the MASTER LRA data from VTube-LASER's main memory into this Bender Setup screen.<br><br> | # If the blue columns only have zeros, or there are no rows in the LRA grid, bring new part data into the Bender Setup window by using the Setup this Window button on the right. Click on "Copy MASTER LRA to Setup LRA". This will bring the MASTER LRA data from VTube-LASER's main memory into this Bender Setup screen.<br><br> |
Revision as of 16:32, 2 December 2016
VTube-LASER uses the legacy Eaton Leonard Current Loop protocol to communicate with Premier controls. The protocol requires that an RS-232 signal be converted to Current Loop, then sent to the bender. |
Contents |
HOW TO SWITCH COMMUNICATIONS ON AT THE PREMIER CONTROL
Communications between VTube-LASER and the Premier is very easy to do because it's robust and also very intuitive.
The VECTOR 1 Menu
All communications from the PREMIER control occurs in the VECTOR 1 screen shown here. |
Premier Communications Active
To put the Premier in communications mode, make the REQUEST TRANSFER box active (green) like is shown here. The WAITING field will be highlighted. CHECK 1 - CORRECT MODE IS ACTIVE |
HOW TO SEND NEW PART DATA FROM VTUBE-LASER TO THE PREMIER CONTROL
VTube-LASER (v2.7 or higher) will allow for the complete setup of all bender and setup data that can be stored in a Premier control in the VTube-LASER Eaton Leonard Setup window. (Note: Even though this tutorial covers mainly the Premier control, this data is also compatible with older EL-2000 and Velog controls.) Click on the image on the right to see a closeup of the Eaton Leonard Setup window. You enter this window to setup the bender parameters. |
|
STEPS TO SEND A NEW PART
|
Other Pages
- See VTube-LASER to Premier, EL2000, Velog Data Transfer
- Back to the Benderlink Ethernet Module Page
- Back to VTube-LASER
- Back to Eaton Leonard