=NEW: Tube Support Location is now Programmable=
+
=ENHANCED: Hardware Key Handling=
 +
 
 +
* The hardware keys used for CNC Bender now require an appropriate program ID in both the time-limited and the permanent hardware key.
  
The '''tube-support up/down location''' relative to the Feed axis can now be changed at the CNC Bender operator station.  It is changed in the '''[[InitAxes Processlist]]''' in the Low Level menu.  Every time the axes are initialized, CNC Bender sets this value.  It can be changed by adjusting the [[COMDEF]] line: <tt>FeedAxisPLS5 = LSL0:0, LSU0:1500</tt>
 
  
 
The LSL parameter is reserved for the '''Limit Switch''' Lower value.  This is where the output for the tube support switches to active.  The appropriate value is usually a Feed axis value of 0 units (millimeters).  The LSU parameter is reserved for the Limit Switch Upper value.  The appropriate value is the position to control at which forward feed position the tube support begins to drop.  The value is always indicated in millimeters.  Floating point values are allowed.  The integer value after the LSL or LSU indicates the index position of the CIO inside the COMDEF.  In this case, the index is 0, which is the first position in the list of CIO objects.
 
The LSL parameter is reserved for the '''Limit Switch''' Lower value.  This is where the output for the tube support switches to active.  The appropriate value is usually a Feed axis value of 0 units (millimeters).  The LSU parameter is reserved for the Limit Switch Upper value.  The appropriate value is the position to control at which forward feed position the tube support begins to drop.  The value is always indicated in millimeters.  Floating point values are allowed.  The integer value after the LSL or LSU indicates the index position of the CIO inside the COMDEF.  In this case, the index is 0, which is the first position in the list of CIO objects.

Revision as of 19:34, 2 July 2007

Cncbender v10-20070702 splash procontrol full.jpg

Contents


REVISION Information

10-20070707, July 2, 2007


NEW: LiteControl GUI Update

The LiteControl now features the same updated GUI as the ProControl. It also requires the the higher screen resolution of 1024 x 768. (The older 800 x 600 is too low for the new software.)




NEW: Splash / Version Screen Shows License Type

CNC Bender can use one of four license models:

  • ProControl Full
  • ProControl Offline
  • LiteControl Full
  • LiteControl Offline

During startup or display of the version screen, the license type is displayed. For example, this shows the OFFLINE license type is running:

Cncbender v10-20070702 splash procontrol offline.jpg




ENHANCED: Hardware Key Handling

  • The hardware keys used for CNC Bender now require an appropriate program ID in both the time-limited and the permanent hardware key.


The LSL parameter is reserved for the Limit Switch Lower value. This is where the output for the tube support switches to active. The appropriate value is usually a Feed axis value of 0 units (millimeters). The LSU parameter is reserved for the Limit Switch Upper value. The appropriate value is the position to control at which forward feed position the tube support begins to drop. The value is always indicated in millimeters. Floating point values are allowed. The integer value after the LSL or LSU indicates the index position of the CIO inside the COMDEF. In this case, the index is 0, which is the first position in the list of CIO objects.

The CIO object is a SERVO MODULE COMMAND. The Modbus OpCode for setting programmable limit switches is 2013 for the first axis in a card, and 2014 for the second axis in a card. See the CIO library's "FeedAxisPLS5" CIO object to see how to setup a new CIO that an address any programmable limit switch. The first word value controls which output to address:

Word 1 value...
- is 0 to set output 1
- is 1 to set output 2
- is 2 to set output 3
- is 3 to set output 4
- is 4 to set output 5
- is 5 to set output 6
- is 6 to set output 7
- is 7 to set output 8

Words 2 and 3 are set aside for the low value. The LSL parameter stuffs values into these two words in a process list line. Words 4 and 5 are set aside for the high value The LSU parameter stuffs values into these two words in a process list line.

Ciodictionary opcode 2013 setup.jpg

The programmable limit switch values can be monitored using the I2T Module Interface software. Use the Programmable Limit Switches feature.

I2t moduleinterface pls axis1.jpg