Difference between revisions of "VTube Communication for CRIPPA Supravision"

From ATTWiki
Jump to: navigation, search
(Allow a Technician to Configure the CRIPPA and the VTube Computers)
(Allow a Technician to Configure the CRIPPA and the VTube Computers)
Line 73: Line 73:
 
# Setup Supravision network communications<br><br>
 
# Setup Supravision network communications<br><br>
 
# Share a CRIPPA folder and setup permissions for the VTube computer to read and write data to that folder.
 
# Share a CRIPPA folder and setup permissions for the VTube computer to read and write data to that folder.
 +
</td>
 +
<td width=300>
 +
</td>
 +
</tr>
 +
</table>
 +
<br><br>
 +
 +
 +
==Test the Network Connection on the VTube Computer==
 +
<table>
 +
<tr valign=top>
 +
<td width=500>
 +
Test the network connection at the VTube computer.
 +
# Open the File Explorer.<br><br>
 +
# Type in the network path for the CRIPPA computer.  It is safest to use a fixed IP in the path like this:  \\192.168.0.200<br><br>
 +
# Press Enter and allow the VTube
 
</td>
 
</td>
 
<td width=300>
 
<td width=300>

Revision as of 17:40, 11 August 2017

Vtube-step logo 2.pngVtube-laser logo 1.96.pngRed crippa logo.png

Crippa942LEol.png

This page describes the setup and use of the VTube to CRIPPA Supravision file communications for newer CRIPPA benders that have the SVNET protocol. Descriptions for VTube-STEP and VTube-LASER is included.

Some of these steps require technical assistance from a CRIPPA or Advanced Tubular Technologies technician to complete the connection.

Contents


Protocol

VTube-STEP can send data directly to the CRIPPA UII software YBC values.

VTube-LASER can correct data in CRIPPA UII for YBC bender corrections.

Vtube-laser communication with CRIPPA.png

Plug in Cable 2 In The CRIPPA HMI Computer

  • Connect the CRIPPA bender to the network following the CRIPPA tech support instructions.

  • Be sure that ethernet cable 2 is plugged into port 2 on the CRIPPA HMI computer. The cable is stored initially under the keyboard shelf. You will need to drop the bottom of the shelf and uncoil the cable through the back like shown on the right.

  • Plug in cable 2 to port 2, then cable tie the cable to the other cables so that it will not bind when the door closes.

  • Be careful to NOT unplug or replace cable 1. This cable allows the CRIPPA software to communicate with the PLC inside the bender.

CRIPPA RJ45 Cable 2 From Under Keyboard Shelf.png

CRIPPA RJ45 Cable 2 Plugged in.png


Plug The Other End of the Cable Into A Network Switch

  • Find cable 2 inside the electrical cabinet on the back of the bender. This is the other end of the same cable you plugged in above.

  • Plug this end of the cable into a network switch.

  • Plug another cable from the network switch into the VTube computer.



Allow a Technician to Configure the CRIPPA and the VTube Computers

These steps require technician-level assistance from CRIPPA or Advanced Tubular Technologies.

The technician will...

  1. Setup the IP address inside the CRIPPA HMI computer and inside the VTube computer

  2. Setup Supravision network communications

  3. Share a CRIPPA folder and setup permissions for the VTube computer to read and write data to that folder.




Test the Network Connection on the VTube Computer

Test the network connection at the VTube computer.

  1. Open the File Explorer.

  2. Type in the network path for the CRIPPA computer. It is safest to use a fixed IP in the path like this: \\192.168.0.200

  3. Press Enter and allow the VTube



Setup Benderlink at VTube-STEP or VTube-LASER

Entering Benderlink Setup

  1. Enter the VTube System Options menu.

  2. Enter the Measure 2 tab menu.

  3. Enter the Setup Benderlink Network menu.

VTube System Options Benderlink Network Button.png

Setup the Benderlink Network Grid for the CRIPPA MPF Bender

  1. Choose an unused row in the grid for a new CRIPPA bender setup. (Click on the image at the right to see a zoomed image.)

  2. Assign a bender name that will help operators identify which bender this is. This text will be displayed at the top of the Bender Setup menu.

  3. Assign the CRIPPA MPF protocol.

  4. Enter the path to the shared drive or folder in the NetPath field. This path should point to the folder that contains either MPF files or folders of MPF files at the CRIPPA bender. VTube accepts UNC names as well as regular paths with drive letters.

  5. Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)

  6. If the Crippa rotates the Clockwise positive, then select YES in the CW Rotation Positive cell.

  7. Press Close to save the settings. VTube will save these values to a persistent configuration file that will not change unless you change them in this grid.

Vtube-step 2.7 crippa mpf benderlink setup.png


How to SEND MASTER XYZ Data to the CRIPPA Control from VTube-STEP

You can import data or models into VTube-STEP then send the calculated LRA bender data to the CRIPPA bender using the VTube EXPORT menu.

STEP 1 - Go the the EXPORT Menu

In the EXPORT menu, click on the CRIPPA MPF button.

Vtube-step 2.7 export crippa mpf.png

STEP 2 - BUILD the File

Set the check boxes for the options you want to use, then press Build New Crippa MPF File.

Vtube-step 2.7 crippa export windows pointer to build.png

STEP 3 - SETUP the Network Path

If the path to the bender is not in the Path Manager list, then you can Add a New Persistent Path to find the path to the bender. If it is in the list, then double click on that path.

Vtube-step 2.7 crippa export add a new path.png

STEP 4 - Choose a New SAVE File Name

Choose the new part name to create in the Save File dialog. Press the SAVE button.

Vtube-step 2.7 crippa export save file dialog.png

STEP 5 - LOAD the MPF File at the CRIPPA Control

At the CRIPPA control, open the new MPF file.

Crippa bender with siemens control.png



How to SEND MASTER LRA Data to the CRIPPA Control from VTube-LASER

You can also send the new LRA data from the VTube-LASER BENDER SETUP menu to the CRIPPA bender using the VTube Bender Output menu.

STEP 1 - Enter the BENDER SETUP menu in VTube-LASER

Press the "BENDER SETUP button in the Navigation Pane.

Vtube-laser 2.7 bendersetup button navigationpane.png


STEP 2 - Choose the BENDER NUMBER

Set the correct bender number at the top of the window.

You can select up to 100 different benders.

You should see a CRIPPA bender at the top left corner of the screen. The Bender Protocol should say "CRIPPA MPF Data File". (This assumes that you have already configured VTube's Benderlink in the Systems Options as described in the previous VTube-STEP section.)

Vtube-laser 2.7 bender setup select crippa bender.png


STEP 3 - Setup the Bender Setup Data in this WINDOW

This is for first-time setup for a new part. This ensures that the correct data is sent to the CRIPPA. Data in this window is separate from data in the main VTube-LASER window, so it is necessary to bring data into this window when performing first-time setup of a part.

  • Click on "Setup this Window" in the expanding menu on the right.

  • Click on copy MASTER LRA to SETUP LRA.

  • Be sure every field in the top panel has data that you want to send to the CRIPPA. The MPF file will contain everything in that panel except for the WALL THICKNESS.

  • The blue columns below will eventually be converted to new YBC data at the bender. So check for numbers there.

  • The radius column should contain the correct bend radii. This column will also be sent to the CRIPPA.

Vtube-laser 2.7 bender setup crippa setup the window.png

STEP 3 - Send data to the CRIPPA BENDER

This step will send new YBC data to a CRIPPA MPF File.

  • Click on "AUTO SEND the MASTER XYZ + BLUE Columns to the Bender".

Note: For this protocol, the XYZ data is not sent. The CRIPPA file only contains LRA data converted to YBC data.

Vtube-laser 2.7 bender setup crippa setup the bender.png

STEP 4 - The SEND SUCCESS Window Should Appear

A timed "SUCCESS" window should appear for a few seconds.

Vtube-laser 2.7 crippa send new save to crippa file success.png

STEP 5 - LOAD the new MPF File at the CRIPPA Control

At the CRIPPA control, open the new MPF file.

Crippa bender with siemens control.png




How to SEND CORRECTION Data to the CRIPPA Control from VTube-LASER

STEP 1 - Bend the Tube

Bend the tube in the CRIPPA.

Crippa bending pipe.png

STEP 2 - Measure the tube with VTube-LASER

Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.



In the VTube-LASER screen shot, you see the actual result of the first tube not qualifying in shape. The red cells in the tangent point grid on the lower left show that the measured tube centerline is out-of-tolerance.

Vtube-laser 2.7 measure not qualify crippa.png

STEP 3 - Enter BENDER SETUP

Press the "BENDER SETUP button in the Navigation Pane.

Vtube-laser 2.7 bendersetup button navigationpane.png

STEP 4 - Choose the BENDER NUMBER

Set the correct bender number at the top of the window.

You can select up to 100 different benders.

You should see a CRIPPA bender at the top left corner of the screen. The Bender Protocol should say "CRIPPA MPF Data File". (This assumes that you have already configured VTube's Benderlink in the Systems Options as described in the previous VTube-STEP section.)

Vtube-laser 2.7 bender setup select crippa bender.png

STEP 5 - RECALL CRIPPA YBC data

In the Bidirectional Communication menu on the right, click on RECALL.

This is a critical step during correction. If a RECALL is not performed before a CORRECTION, then VTube may not be able to properly sort out what is the NOMINAL data and what is the ADJUSTED in the MPF file. Be sure to perform this step before performing the CORRECTION step below.

Vtube-laser 2.7 crippa recall.png

STEP 6 - LOAD the CRIPPA File Data

In the Open File dialog, select the MPF file that you intend to correct and press Open.

This will update the BLUE columns in the Bender Setup, and also update the internal CRIPPA MPF data object that keeps the NOMINAL and ADJUSTED values separate from each other in the YBC data.

Vtube-laser 2.7 crippa recall open mpf file.png

STEP 7 - Manually Setup the ADJUSTMENT Values

You can manually change the ADJUSTMENT values before sending corrections. Some customers like to set the first and last Length adjustment to zero in order to keep the start position of the carriage in the same place - for when they have extra length on the ends.

Vtube-laser 2.7 crippa adjust adjustments.png

STEP 8 - Send the CORRECTION Values to the CRIPPA MPF File

Click on AUTO SEND. This will send the ORANGE columns to the CRIPPA bender.

To be sure that a RECALL has recently been performed, VTube will show a CRIPPA CORRECTIONS NOTES as a reminder.

The dialog also explains what happens next.

Vtube-laser 2.7 crippa send corrections.png

STEP 9 - Choose a CRIPPA MPF File to CORRECT

Choose the CRIPPA file that you want to correct.

Press the SAVE button.

Vtube-laser 2.7 crippa send corrections save to crippa file.png

STEP 10 - The SEND SUCCESS Window Should Appear

A timed "SUCCESS" window should appear for a few seconds.

Vtube-laser 2.7 crippa send corrections save to crippa file success.png

STEP 11 - LOAD the corrected MPF File at the CRIPPA Control

At the CRIPPA control, open the corrected MPF file.

Go back to STEP 1 above and repeat the process until the part is within the envelope tolerance allowed.

Crippa bender with siemens control.png



Other Pages