|
|
Line 68: |
Line 68: |
| <tr valign=top> | | <tr valign=top> |
| <td width=500> | | <td width=500> |
− | '''These steps require technician-level assistance from CRIPPA or Advanced Tubular Technologies.'''<br><br>
| + | <font size=3>[[image:Gear_warning.jpg]] <b>These steps require technician-level assistance from CRIPPA or Advanced Tubular Technologies.</b><br><br></font><br><br> |
| The technician will... | | The technician will... |
| # Setup the IP address inside the CRIPPA HMI computer and inside the VTube computer<br><br> | | # Setup the IP address inside the CRIPPA HMI computer and inside the VTube computer<br><br> |
Line 79: |
Line 79: |
| </table> | | </table> |
| <br><br> | | <br><br> |
− |
| |
| | | |
| ==Test the Network Connection on the VTube Computer== | | ==Test the Network Connection on the VTube Computer== |
Revision as of 18:20, 11 August 2017
This page describes the setup and use of the VTube to CRIPPA Supravision file communications for newer CRIPPA benders that have the SVNET protocol. Descriptions for VTube-STEP and VTube-LASER is included.
Some of these steps require technical assistance from a CRIPPA or Advanced Tubular Technologies technician to complete the connection.
|
|
Protocol
VTube-STEP can send data directly to the CRIPPA UII software YBC values.
VTube-LASER can correct data in CRIPPA UII for YBC bender corrections.
|
|
Plug in Cable 2 In The CRIPPA HMI Computer
- Connect the CRIPPA bender to the network following the CRIPPA tech support instructions.
- Be sure that ethernet cable 2 is plugged into port 2 on the CRIPPA HMI computer. The cable is stored initially under the keyboard shelf. You will need to drop the bottom of the shelf and uncoil the cable through the back like shown on the right.
- Plug in cable 2 to port 2, then cable tie the cable to the other cables so that it will not bind when the door closes.
- Be careful to NOT unplug or replace cable 1. This cable allows the CRIPPA software to communicate with the PLC inside the bender.
|
|
Plug The Other End of the Cable Into A Network Switch
- Find cable 2 inside the electrical cabinet on the back of the bender. This is the other end of the same cable you plugged in above.
- Plug this end of the cable into a network switch.
- Plug another cable from the network switch into the VTube computer.
|
|
Allow a Technician to Configure the CRIPPA and the VTube Computers
These steps require technician-level assistance from CRIPPA or Advanced Tubular Technologies.
The technician will...
- Setup the IP address inside the CRIPPA HMI computer and inside the VTube computer
- Setup Supravision network communications
- Share a CRIPPA folder and setup permissions for the VTube computer to read and write data to that folder.
|
|
Test the Network Connection on the VTube Computer
Test the network connection at the VTube computer using the Windows File Explorer.
- Open the File Explorer.
- Type in the network path for the CRIPPA computer. It is safest to use a fixed IP in the path like this: \\192.168.0.200
(The 192.168.0.200 is only an example IP address. The number you will use will most likely be something different.)
- Press Enter and allow the VTube to connect to the CRIPPA computer. This may take a few seconds.
- The CRIPPA computer will ask you to supply credentials (username and password).
- Enter the credentials supplied by the CRIPPA or Advanced Tubular technician, then be sure the check the "Remember my credentials" checkbox before pressing OK.
- If the connection works, then you will see a couple of folders in the File Explorer screen. One of them will be something like "SVTransfer". Double click on that folder. The path that you see in the top of the Explorer window is the path you will need to program into VTube for communications to the CRIPPA. So, for this example, the path to use in setting up VTube is "\\192.168.0.200\SVTransfer".
- Attempt to create a new text file in this folder. If you can, then the network connection is complete. (VTube must be allowed to write files to this folder.)
|
|
Setup Benderlink at VTube-STEP or VTube-LASER
Entering Benderlink Setup
- Enter the VTube System Options menu.
- Enter the Measure 2 tab menu.
- Enter the Setup Benderlink Network menu.
|
|
Setup the Benderlink Network Grid for the CRIPPA MPF Bender
- Choose an unused row in the grid for a new CRIPPA bender setup. (Click on the image at the right to see a zoomed image.)
- Assign a bender name that will help operators identify which bender this is. This text will be displayed at the top of the Bender Setup menu.
- Assign the CRIPPA MPF protocol.
- Enter the path to the shared drive or folder in the NetPath field. This path should point to the folder that contains either MPF files or folders of MPF files at the CRIPPA bender. VTube accepts UNC names as well as regular paths with drive letters.
- Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)
- If the Crippa rotates the Clockwise positive, then select YES in the CW Rotation Positive cell.
- Press Close to save the settings. VTube will save these values to a persistent configuration file that will not change unless you change them in this grid.
|
|
How to SEND MASTER XYZ Data to the CRIPPA Control from VTube-STEP
You can import data or models into VTube-STEP then send the calculated LRA bender data to the CRIPPA bender using the VTube EXPORT menu.
In the EXPORT menu, click on the CRIPPA MPF button.
|
|
STEP 2 - BUILD the File
Set the check boxes for the options you want to use, then press Build New Crippa MPF File.
|
|
STEP 3 - SETUP the Network Path
If the path to the bender is not in the Path Manager list, then you can Add a New Persistent Path to find the path to the bender. If it is in the list, then double click on that path.
|
|
STEP 4 - Choose a New SAVE File Name
Choose the new part name to create in the Save File dialog. Press the SAVE button. |
|
STEP 5 - LOAD the MPF File at the CRIPPA Control
At the CRIPPA control, open the new MPF file. |
|
How to SEND MASTER LRA Data to the CRIPPA Control from VTube-LASER
You can also send the new LRA data from the VTube-LASER BENDER SETUP menu to the CRIPPA bender using the VTube Bender Output menu.
Press the "BENDER SETUP button in the Navigation Pane.
|
|
STEP 2 - Choose the BENDER NUMBER
Set the correct bender number at the top of the window.
You can select up to 100 different benders.
You should see a CRIPPA bender at the top left corner of the screen. The Bender Protocol should say "CRIPPA MPF Data File". (This assumes that you have already configured VTube's Benderlink in the Systems Options as described in the previous VTube-STEP section.)
|
|
STEP 3 - Setup the Bender Setup Data in this WINDOW
This is for first-time setup for a new part. This ensures that the correct data is sent to the CRIPPA. Data in this window is separate from data in the main VTube-LASER window, so it is necessary to bring data into this window when performing first-time setup of a part.
- Click on "Setup this Window" in the expanding menu on the right.
- Click on copy MASTER LRA to SETUP LRA.
- Be sure every field in the top panel has data that you want to send to the CRIPPA. The MPF file will contain everything in that panel except for the WALL THICKNESS.
- The blue columns below will eventually be converted to new YBC data at the bender. So check for numbers there.
- The radius column should contain the correct bend radii. This column will also be sent to the CRIPPA.
|
|
STEP 3 - Send data to the CRIPPA BENDER
This step will send new YBC data to a CRIPPA MPF File.
- Click on "AUTO SEND the MASTER XYZ + BLUE Columns to the Bender".
Note: For this protocol, the XYZ data is not sent. The CRIPPA file only contains LRA data converted to YBC data.
|
|
STEP 4 - The SEND SUCCESS Window Should Appear
A timed "SUCCESS" window should appear for a few seconds.
|
|
STEP 5 - LOAD the new MPF File at the CRIPPA Control
At the CRIPPA control, open the new MPF file. |
|
How to SEND CORRECTION Data to the CRIPPA Control from VTube-LASER
STEP 1 - Bend the Tube
Bend the tube in the CRIPPA.
|
|
STEP 2 - Measure the tube with VTube-LASER
Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.
In the VTube-LASER screen shot, you see the actual result of the first tube not qualifying in shape. The red cells in the tangent point grid on the lower left show that the measured tube centerline is out-of-tolerance.
|
|
STEP 3 - Enter BENDER SETUP
Press the "BENDER SETUP button in the Navigation Pane.
|
|
STEP 4 - Choose the BENDER NUMBER
Set the correct bender number at the top of the window.
You can select up to 100 different benders.
You should see a CRIPPA bender at the top left corner of the screen. The Bender Protocol should say "CRIPPA MPF Data File". (This assumes that you have already configured VTube's Benderlink in the Systems Options as described in the previous VTube-STEP section.)
|
|
STEP 5 - RECALL CRIPPA YBC data
In the Bidirectional Communication menu on the right, click on RECALL.
This is a critical step during correction. If a RECALL is not performed before a CORRECTION, then VTube may not be able to properly sort out what is the NOMINAL data and what is the ADJUSTED in the MPF file. Be sure to perform this step before performing the CORRECTION step below.
|
|
STEP 6 - LOAD the CRIPPA File Data
In the Open File dialog, select the MPF file that you intend to correct and press Open.
This will update the BLUE columns in the Bender Setup, and also update the internal CRIPPA MPF data object that keeps the NOMINAL and ADJUSTED values separate from each other in the YBC data.
|
|
STEP 7 - Manually Setup the ADJUSTMENT Values
You can manually change the ADJUSTMENT values before sending corrections. Some customers like to set the first and last Length adjustment to zero in order to keep the start position of the carriage in the same place - for when they have extra length on the ends.
|
|
STEP 8 - Send the CORRECTION Values to the CRIPPA MPF File
Click on AUTO SEND. This will send the ORANGE columns to the CRIPPA bender.
To be sure that a RECALL has recently been performed, VTube will show a CRIPPA CORRECTIONS NOTES as a reminder.
The dialog also explains what happens next.
|
|
STEP 9 - Choose a CRIPPA MPF File to CORRECT
Choose the CRIPPA file that you want to correct.
Press the SAVE button.
|
|
STEP 10 - The SEND SUCCESS Window Should Appear
A timed "SUCCESS" window should appear for a few seconds.
|
|
STEP 11 - LOAD the corrected MPF File at the CRIPPA Control
At the CRIPPA control, open the corrected MPF file.
Go back to STEP 1 above and repeat the process until the part is within the envelope tolerance allowed. |
|
Other Pages