Difference between revisions of "CNC Bender v10-20070928"
From ATTWiki
Line 13: | Line 13: | ||
Now CNC Bender software uses the FEED torque limiting values programmed into the Low Level menu to ensure that any torque levels outside the range are moved into the valid range. This will protect the carriage against very low or high torque values in the CNC Bender Process List. | Now CNC Bender software uses the FEED torque limiting values programmed into the Low Level menu to ensure that any torque levels outside the range are moved into the valid range. This will protect the carriage against very low or high torque values in the CNC Bender Process List. | ||
</ul> | </ul> | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
=Changes to CNC Bender User Interface= | =Changes to CNC Bender User Interface= | ||
− | ===Update to File User Interface=== | + | ===Update to File Load User Interface=== |
[[image:Cncbender_fileload.jpg|300px]] | [[image:Cncbender_fileload.jpg|300px]] | ||
Line 31: | Line 22: | ||
<ul> | <ul> | ||
− | CNC Bender's | + | CNC Bender's FILE LOAD menu is reworked significantly based on customer input. |
* There is no more multiple path selection with Alias names. This was very confusing for operators, so it has been removed. | * There is no more multiple path selection with Alias names. This was very confusing for operators, so it has been removed. | ||
− | * The | + | * The menu now expands to fill the screen of an operator station. |
+ | * The menu has a new file display window that will show the information inside the selected file. This allows you to instantly view the data inside that file before loading it into memory. | ||
+ | * The selection of a new and custom path is much simpler. | ||
+ | * The custom path is considered temporary. It is only used in the current session for that window. | ||
+ | * The custom path feature requires a password for use. | ||
+ | |||
Revision as of 00:52, 29 September 2007
Contents |
Change to CNC Bender Process List Builder
Automatic FEED Torque Limit When Outside of Range
-
Now CNC Bender software uses the FEED torque limiting values programmed into the Low Level menu to ensure that any torque levels outside the range are moved into the valid range. This will protect the carriage against very low or high torque values in the CNC Bender Process List.
Changes to CNC Bender User Interface
Update to File Load User Interface
-
CNC Bender's FILE LOAD menu is reworked significantly based on customer input.
- There is no more multiple path selection with Alias names. This was very confusing for operators, so it has been removed.
- The menu now expands to fill the screen of an operator station.
- The menu has a new file display window that will show the information inside the selected file. This allows you to instantly view the data inside that file before loading it into memory.
- The selection of a new and custom path is much simpler.
- The custom path is considered temporary. It is only used in the current session for that window.
- The custom path feature requires a password for use.
How to UPGRADE
If your operator station contains one of the versions listed below, then they can be upgraded through simple self-installation:
- CNC Bender v10-20070920
- CNC Bender v10-20070726b
- CNC Bender v10-20070803
- CNC Bender v10-20070828
- CNC Bender v10-20070914
Please contact Advanced Tubular Technologies for upgrade information.