Difference between revisions of "VTube Communications With Transfluid Benders"
(→STEPS) |
(→Configuration Settings) |
||
Line 87: | Line 87: | ||
</table> | </table> | ||
− | ===Configuration Settings=== | + | === Notes about the Configuration Settings=== |
− | + | ||
* Bender Number: The Supravision network protocol requires that every bend have a unique number if the benders are sharing the same network path for communications.<br><br> | * Bender Number: The Supravision network protocol requires that every bend have a unique number if the benders are sharing the same network path for communications.<br><br> | ||
− | * Paths: These are the paths used for VTube-LASER to communicate with the | + | * Paths: These are the paths used for VTube-LASER to communicate with the tProject software.<br><br> |
− | * Timeouts: These are timeouts that allow the | + | * Timeouts: These are timeouts that allow the tProject to know when it has waited too long for data to move in either direction.<br><br> |
− | + | ||
− | + | ||
− | + | ||
− | + | ||
− | + | ||
</td> | </td> | ||
<td width=300> | <td width=300> |
Revision as of 20:06, 29 March 2021
This page describes the use of the VTube-LASER to Transfluid bender corrections. |
Back to VTube-LASER
Contents |
Transfluid SVNet Communications Protocol in VTube-LASER and VTube-STEP
As of version 3.0 build 456, we've embedded the Transfluid SVNET protocol in VTube-STEP and VTube-LASER. |
Configuring Transfluid tProject for Communications
Follow these steps in Transfluid tProject to set up communications for VTube-LASER and VTube-STEP |
SET UP STEPS
STEP 1
Click on the blue button wrench/screwdriver button in the upper right corner of the user interface. |
STEP 2
Click on the Import/Export tab. |
STEP 3
Enter the set up data in the Import box.
|
Notes about the Configuration Settings
- Bender Number: The Supravision network protocol requires that every bend have a unique number if the benders are sharing the same network path for communications.
- Paths: These are the paths used for VTube-LASER to communicate with the tProject software.
- Timeouts: These are timeouts that allow the tProject to know when it has waited too long for data to move in either direction.
</td> <td width=300> </td> </tr> </table>
Using the OMCG Easy Programming 4 Measuring System Interface
Click on the Measuring System button in the toolbar to load the Measure System Interface. NOMINAL EXPORT
NOMINAL IMPORT
CORRECTIONS
|
|
OMCG Documentation from OMCG
This is the official OMCG Document (PDF - English) for setup and use of the OMCG SVNET protocol. Download the OMCG PDF Setup Document |
Other Pages
- See VTube-LASER