About this Page
This page describes the setup and use of the recommended BLM communications protocol for VTube. |
General Communications Setup at the BLM Bender for Both Protocols
|
PROTOCOL 1: BLM SVNET PROTOCOL (SW0453)
Use the BLM SVNET NETWORK PROTOCOL for CORRECTING the BLM
VTube-LASER supports the BLM SVNET protocol for correction. BLM SUPRAVISION PROTOCOL - PreferredThis is the communications protocol that we recommend you use.
|
BLM SVNET CORRECTIONS PROTOCOL: The Capabilities
|
BLM CMM CORRECTIONS PROTOCOL: Setup Benderlink at VTube-LASER with the BLM CMM Protocol
Entering Benderlink Setup
|
Setup the Benderlink Network Grid for the BLM SVNET Protocol
|
BLM SVNET PROTOCOL: How to SEND CORRECTION Data to the BLM Control from VTube-LASER
Bend the Part on the BLM then Open Measuring Center CommunicationsClick on the measuring center image to the right of the part number.
|
Measure the tube with VTube-LASERMeasure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.
|
Correct the BLM with VTube-LASER - Enter BENDER SETUP
Follow these steps in the VTube-LASER: Press the "BENDER SETUP button in the Navigation Pane. |
INITIAL RECALL Setup of Bender Setup Window
These steps assume that you have programmed a part into the bender and that you have measured and aligned a part. STEP 1 - Set the correct bender number at the top of the window. The BLM SVNET bender icon should display if you have already set up the bender protocol in the Benderlink grid.
|
RECALL Warning Boxes
VTube-LASER will probably warn you that the incoming data count and part number does not match what is in VTube-LASER.
|
THE BLUE COLUMNS SHOULD MATCH THE BLM XYZc DATA AFTER THE RECALL
After the RECALL, the blue columns should show the data that is programmed in the BLM control. |
SEND THE CORRECTIONS TO THE BLM FILE
SAVE the Correction data to the file for the BLM by pressing AUTO SEND BENDER CORRECTIONS.
|
AT THE BLM, Close the Communications Window
If you saved the orange columns of data from VTube-LASER to the BLM, then you can close the communications window at the BLM and then check the new XYZ bender values. Be sure that they match the data in the orange cells in VTube. |
SIMULATE and RUN
|
IMPORTANT RULES for CORRECTIONS LOOPS
|
See also VTube Communication for BLM VGP3D - Alternative Protocols