Difference between revisions of "Benderlink for CNC Bender"
From ATTWiki
(→How CNC Bender and Benderlink Interact) |
(→How CNC Bender and Benderlink Interact) |
||
Line 9: | Line 9: | ||
# CNC Bender must be in MANUAL mode, or CNC Bender will not allow for the transfer.<br><br> | # CNC Bender must be in MANUAL mode, or CNC Bender will not allow for the transfer.<br><br> | ||
− | # To send NEW data, be sure that the FRB data in CNC Bender is cleared. There should be all zeros in all six fields of the first row. There should only be one row.<br><br>[[image:Cncblink_frb_beforeblink_new.jpg|350px]] | + | # To send NEW data, be sure that the FRB data in CNC Bender is cleared. There should be all zeros in all six fields of the first row. There should only be one row.<br><br>[[image:Cncblink_frb_beforeblink_new.jpg|350px]]<br><br> |
# If data other than all ZEROS is in the FRB page, then Benderlink will assume that you are correcting an existing part and MERGE the corrections into the ADJUSTMENT fields.<br><br> | # If data other than all ZEROS is in the FRB page, then Benderlink will assume that you are correcting an existing part and MERGE the corrections into the ADJUSTMENT fields.<br><br> | ||
# If an operator intends to receive a NEW part, but forgets to clear the FRB screen, then he will find a morphed part on the screen. The existing part will have been corrected with the wrong data.<br><br> | # If an operator intends to receive a NEW part, but forgets to clear the FRB screen, then he will find a morphed part on the screen. The existing part will have been corrected with the wrong data.<br><br> |
Revision as of 19:20, 25 February 2008
How CNC Bender and Benderlink Interact
CNC Bender software communicates with Benderlink when Benderlink either requests data or sends data. These are the simple rules for using Benderlink in CNC Bender:
- CNC Bender must be in MANUAL mode, or CNC Bender will not allow for the transfer.
- To send NEW data, be sure that the FRB data in CNC Bender is cleared. There should be all zeros in all six fields of the first row. There should only be one row.
- If data other than all ZEROS is in the FRB page, then Benderlink will assume that you are correcting an existing part and MERGE the corrections into the ADJUSTMENT fields.
- If an operator intends to receive a NEW part, but forgets to clear the FRB screen, then he will find a morphed part on the screen. The existing part will have been corrected with the wrong data.