Difference between revisions of "Diagnostic Steps for Master Power On Problems"
From ATTWiki
Line 6: | Line 6: | ||
#Press the '''NETWORK INFO''' tab | #Press the '''NETWORK INFO''' tab | ||
#Your Operator Station IP Address will be listed | #Your Operator Station IP Address will be listed | ||
+ | |||
+ | If the Operator Station IP address DOES NOT begin with "192.168.0" then all CNC Bender will not be able to communicate with the Modules and the CNC Bender software will not functional. (CNC Bender uses a Class C network standard, which requires the first three octet values be identical for every device on the network. Most SMT/ATT CNC Benders use a Net Indentifier of "192.168.0") |
Revision as of 17:25, 29 June 2006
Diagnosing Master Power On Issues
There are a number of diagnostics that you can perform if you experience problems starting the master power on your SMT/ATT CNC Bender. Step through these diagnostics to resolve master power issues.
Check the IP Address of the Operator Station
- Press the SYSTEM button
- Press the NETWORK INFO tab
- Your Operator Station IP Address will be listed
If the Operator Station IP address DOES NOT begin with "192.168.0" then all CNC Bender will not be able to communicate with the Modules and the CNC Bender software will not functional. (CNC Bender uses a Class C network standard, which requires the first three octet values be identical for every device on the network. Most SMT/ATT CNC Benders use a Net Indentifier of "192.168.0")