Difference between revisions of "VTube-LASER v1.66"
Line 30: | Line 30: | ||
<br><br> | <br><br> | ||
− | ===[[image:Check.jpg|25px]] NEW: | + | ===[[image:Check.jpg|25px]] NEW: In-Process Bend Correction=== |
− | [[image:vtube- | + | [[image:vtube-laser_1_66_bendangletransfer.jpg|500px]]<br><br> |
<table cellpadding=10> | <table cellpadding=10> | ||
<tr valign=top> | <tr valign=top> | ||
<td width=200> | <td width=200> | ||
− | The | + | The new Bend Angle Transfer menu allows VTube to correct bends while still in the bender.<br><br> |
− | * | + | * The bender forms a bend.<br> |
− | * | + | * The clamp opens and the bender pauses.<br> |
+ | * The operator moves the FARO arm next to the bender and measures the single bend.<br> | ||
+ | * The bend angle is transferred to the Bend Angle Transfer menu.<br> | ||
+ | * The bend angle is sent to the bender control.<br> | ||
+ | * The bender control uses the data to close the clamp and adjust the bend angle.<br> | ||
− | The | + | |
+ | The process is continued until the bend angle is within tolerance. The workflow is identical to measuring a single bend off the bender. | ||
</td> | </td> | ||
<td width=300> | <td width=300> | ||
− | [[image:vtube- | + | [[image:vtube-laser_1_66_bendangletransfer_wholescreen.jpg|300px]] |
</td> | </td> | ||
</tr> | </tr> |
Revision as of 17:04, 27 May 2011
Revision 1.66Back to VTube-LASER |
NEW: Save Project Changes Dialog
VTube now tracks if the project has changed and needs to be saved before opening a new project or closing the software. |
NEW: In-Process Bend Correction
The new Bend Angle Transfer menu allows VTube to correct bends while still in the bender.
|
ENHANCED: New Torus-fit Engine for Radius Stripe Scanning
The new radius stripe scanning method is more accurate as of this version of VTube due to a new torus-fit engine included in VTube.
|
NEW: Bender Data + Corrections Data Chart in Reports
A new bender chart was added to the report template to include the bender data + corrections chart |
ENHANCED: Report Preview Menu
The Report Preview menu now allows you to change the printer and the paper orientation before printing. |
ENHANCED: Measure Setup - Laser Probe Grid
The Laser probe grid now has a separate checkbox for automatically enabling either laser or tactile measuring for radius stripe scans. |
ENHANCED: Measure Setup - Scan Rate Grid
The Scan Rate grid now has a separate controls for radius stripe scans. |
Other Changes
|
Issues with this version fixed in newer versions
|
Other Pages
- Back to VTube-LASER
VTube-LASER Training Video - How to perform effective end scans. |