===How To Use This End-Scan Technique===
 
  
<table cellpadding=10>
 
<tr valign=top>
 
<td width=300>
 
* Align the scanner with a slight scissor angle across the end as is shown in the image on the right<br><br>
 
* Attempt to hold the laser motionless when collecting the stripes across the end to increase repeatability.<br><br>
 
* Consistently place the line across the same area of the tube end from measure to measure.<br><br>
 
*Press the green button until VTube-LASER is finished scanning all the end stripes.<br><br>
 
[[image:EndWithScissorCloseup.jpg|300px]]<br><br>
 
</td>
 
<td width=300>
 
[[image:EndWithScissor.jpg|300px]]
 
</td>
 
</tr>
 
</table>
 
  
 
===Other Pages===
 
===Other Pages===

Revision as of 23:58, 10 February 2012

Vtube-laser logo.jpg End Scan Technique Research

Vtube-laser 1 73.jpg


End-Scan Techniques

Measure Setup

  • Set System Options, Measure 2 Tab, "Maximum Number of LLP Points in String" to 3
  • Set Measure Setup - LASER Tab: The LASER defaults to ON for CYLINDERS and END-SCANS.
  • Set Measure Setup - LASER Tab: Cylinder stripes = 3 to 5
  • Set Measure Setup - LASER Tab: End-scan stripes = 5
  • Set Measure Setup - LASER Tab: Split bend stripes = 5
  • Set Measure Setup = Scan Rates Tab: Set all rates to TIMER for all scan types.
  • Set Measure Setup = Scan Rates Tab: Set the Scan Rates TIMER is set to 0 for all TIMERS.