Difference between revisions of "VTube-LASER v1.76.3"

From ATTWiki
Jump to: navigation, search
(25px NEW: Automatic Damping for Correction)
(25px NEW: Automatic Damping for Correction)
Line 35: Line 35:
  
 
So now VTube has two kinds of automatic damping.  The first one reduces the correction by 50% in any of three sets of bender axis data (the Length, Rotation, and Bend).  It allows for this damping in each axis independently – so they can choose the appropriate axis to damp.  The second kind of damping is based on the previous adjustment values.  Using the previous value causes the correction to be reduced even faster if this kind of oscillation exists.
 
So now VTube has two kinds of automatic damping.  The first one reduces the correction by 50% in any of three sets of bender axis data (the Length, Rotation, and Bend).  It allows for this damping in each axis independently – so they can choose the appropriate axis to damp.  The second kind of damping is based on the previous adjustment values.  Using the previous value causes the correction to be reduced even faster if this kind of oscillation exists.
 
 
  
 
</td>
 
</td>
Line 44: Line 42:
 
</tr>  
 
</tr>  
 
</table>
 
</table>
 
 
 
<table cellpadding=10>
 
<table cellpadding=10>
 
<tr valign=top>
 
<tr valign=top>

Revision as of 00:50, 4 April 2012

Vtube-laser logo.jpg

Revision 1.76.3

Back to VTube-LASER
Back to VTube-PRO

Vtube-pro 1 76.3.jpg


Check.jpg NEW: Automatic Damping for Correction

VTube-LASER can now automatically damp correction data in order to avoid oversteer.

Two adjacent 90 degree bends that are close to each other followed by a long straight causes VTube (and other measuring solutions) to overcorrect the end of the long straight. The end is supposed be corrected to the middle straight (the MASTER) like this:

Vtube-automatic proper correction tube swing.jpg

But what this tube configuration does often is a wag-the-tail oscillation in the correction loop like this:

Vtube-automatic proper correction tube swing too much.jpg

The result is the correction causes the leg to overshoot the target.

So now VTube has two kinds of automatic damping. The first one reduces the correction by 50% in any of three sets of bender axis data (the Length, Rotation, and Bend). It allows for this damping in each axis independently – so they can choose the appropriate axis to damp. The second kind of damping is based on the previous adjustment values. Using the previous value causes the correction to be reduced even faster if this kind of oscillation exists.

Vtube-autocorrectiondamping green curve.jpg

So now VTube has two kinds of automatic damping. The first one reduces the correction by 50% in any of three sets of bender axis data (the Length, Rotation, and Bend). It allows for this damping in each axis independently – so they can choose the appropriate axis to damp. The second kind of damping is based on the previous adjustment values. Using the previous value causes the correction to be reduced even faster if this kind of oscillation exists.

Vtube-autocorrectdamping pulldownbox.jpg

Check.jpg Enhanced: Bender Setup Window Redesigned

VTube-LASER's Bender Setup menu was redesigned to fit more options into the window.

Vtube-pro 1 76.3.jpg