Difference between revisions of "VTube-STEP v1.77.3"

From ATTWiki
Jump to: navigation, search
(25px ENHANCED: Changed End Trim Offset Field Names)
(25px NEW: Reset Origin to Zero in XYZ Data)
Line 60: Line 60:
  
  
===[[image:Check.jpg|25px]] NEW:  Reset Origin to Zero in XYZ Data===
+
 
<table cellpadding=10>
+
<tr valign=top>
+
<td width=300>
+
Now you can reset the origin in the XYZ data to ZERO in VTube-STEP.<br><br>
+
</td>
+
<td width=300>
+
[[image:vtube-step_reset_origin.jpg|300px]]
+
</td>
+
</tr>
+
</table>
+
  
 
===[[image:Check.jpg|25px]] REPAIR:  TubeCalc Project File Linear Units Import Properly===
 
===[[image:Check.jpg|25px]] REPAIR:  TubeCalc Project File Linear Units Import Properly===

Revision as of 03:14, 8 August 2012

Vtube-step logo.jpg

Revision 1.77.3

Vtube-step 1.77.3a.jpg



Check.jpg UPDATED: View Orientation Control

The View Orientation Control has new choices with graphics icons of each axes orientation.

You can click on the button or the image to find a new orientation.

Vtube 1.77.3 vieworientation.jpg

Check.jpg NEW: End Lengths Change in Diameter Model with End Adjustment Length Values

When the A-End or B-End Adjustment Lengths change, then the diameter model lengths change automatically at the next redraw. This does not change the centerline end point location.

Vtube 1.77.3 EndLengthShortened.jpg

Check.jpg REPAIR: Cut Length Calculation with End Adjustments

The End Length Adjustments were doubled in the Cut Length calculation. This is repaired in this version.

Vtube endlength cutlength partsetup.jpg






Check.jpg REPAIR: TubeCalc Project File Linear Units Import Properly

Linear units are now always properly imported into VTube from TubeCalc files.

Previous versions would sometimes improperly interpret the Inch or Millimeter setting in the TubeCalc file.

Check.jpg ENHANCED: The Linear Units Switches to the Import File Units

VTube now always switches to the linear units used in the imported TubeCalc, Solid Edge, or Supravision file.


Check.jpg ENHANCED: TubeCalc Project Imports Include More Values

The following values were added to TubeCalc imports in this version:

From TubeCalcTo VTube
Customer NameSmall right green arrow.pngCustomer
Material NameSmall right green arrow.pngMaterial Spec
UserSmall right green arrow.pngAuthor
Material Offset 1Small right green arrow.pngA-End Length Adjust
Material Offset 2Small right green arrow.pngB-End Length Adjust
Measuring Center Offset ASmall right green arrow.pngA-End Measured Offset
Measuring Center Offset BSmall right green arrow.pngB-End Measured Offset




Check.jpg FIXED: Projection Tolerances Now Change Units Properly

The projection tolerance now handles a change in linear units properly.

Projection tolerances allow VTube to know how precise it must be to qualify a projection intersection as successful. Some models have less precise surfaces - so the tolerance needs to be increased for a successful calculation of centerline.

Vtube v1.77 projectiontoleranceedit.jpg

Check.jpg ENHANCED: Report Formatting Updated

The report formatting is updated with larger and bolder tiles.

Vtube v1.77 reportformat.jpg

Other Pages