When scanning the end walls of highly reflective tubing with striations like shown in the image on the right, it is better to either cover the end with a coat of Maganaflux or Dynaflux spray, or cover it with an end target to avoid outlier points.<br><br>
+
When scanning the end walls of highly reflective tubing with striations like shown in the image on the right, it is better to either cover the end with a coat of Maganaflux, Dynaflux, or foot powder spray, or cover it with an end target to avoid outlier points.<br><br>
 
The image below an end target plastic label attached to the end of the same tube.  In this case, there are no striations visible.<br><br>
 
The image below an end target plastic label attached to the end of the same tube.  In this case, there are no striations visible.<br><br>
 
[[image:EndWithEndWall_HighReflective_Striation_EndTarget.jpg|200px]]
 
[[image:EndWithEndWall_HighReflective_Striation_EndTarget.jpg|200px]]

Revision as of 02:43, 29 September 2012

Vtube-laser logo.jpg How to perform the end-wall end scan.

Vtube-laser 1 73.jpg


About the End Wall Orientation

We recommend this for increased precision where it is possible to strike the end wall. high-reflectivity and burrs are not an issue on the end wall of the tube. The End Wall method is also very useful for thicker wall tubes.

For tube walls with high-reflectivity with burrs or saw marks, we recommend either a coating (see below) or the most precise End-Scan Using End Targets.

Measure Setup

  • Set System Options, Measure 2 Tab, "Maximum Number of LLP Points in String" to 3
  • Set Measure Setup - LASER Tab: The LASER defaults to ON for CYLINDERS and END-SCANS.
  • Set Measure Setup - LASER Tab: Cylinder stripes = 3 to 5
  • Set Measure Setup - LASER Tab: End-scan stripes = 5
  • Set Measure Setup - LASER Tab: Split bend stripes = 5
  • Set Measure Setup = Scan Rates Tab: Set all rates to TIMER for all scan types.
  • Set Measure Setup = Scan Rates Tab: Set the Scan Rates TIMER is set to 0 for all TIMERS.

How To Use This End-Scan Technique

  • Align the scanner at the end wall of the tube.

  • Be careful to not allow the laser reflection to strike you in the eyes.

  • Attempt to hold the laser motionless when collecting the stripes across the end to increase repeatability.

  • Consistently place the line across the same area of the tube end from measure to measure.

  • Press the green button until VTube-LASER is finished scanning all the end stripes.

The advantage of this method is that it is easy to use. The disadvantage is that it is more prone to outlier points from the inner diameter surface.

EndWithEndWall1.jpg

Another Way to Use This End-Scan Technique

  • An alternative way to scan the end is to align the scanner so that it touches one end wall of the tube.

The advantage of this method is that it is less prone to outlier points. The disadvantage is that it is hard to aim at thinner walls.