Difference between revisions of "VTube-LASER v1.91"

From ATTWiki
Jump to: navigation, search
(25px Other Changes)
(25px NEW: Direct Communications with Eaton Leonard Premier, EL2000, and Ve-log Benders)
Line 67: Line 67:
 
</tr>
 
</tr>
 
</table>
 
</table>
 +
 +
===[[image:Check.jpg|25px]] NEW: Click on the scanner control labels to load the scanner control===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=400>
 +
* Now you can click on the scanner control lables to load the FARO Scanner control window.<br><br>
 +
</td>
 +
<td width=300>
 +
[[image:vtube-laser-1.91_click_label_load_scanner_control.png|300px]]
 +
</td>
 +
</tr>
 +
</table>
 +
<br><br>
  
 
===[[image:Check.jpg|25px]] NEW: Direct Communications with Eaton Leonard Premier, EL2000, and Ve-log Benders===
 
===[[image:Check.jpg|25px]] NEW: Direct Communications with Eaton Leonard Premier, EL2000, and Ve-log Benders===

Revision as of 18:19, 25 June 2014

Vtube-laser logo.jpg

Revision 1.91


Vtube-laser 1.89 mainscreen.png





Check.jpg NEW: Use Leapfrog To Measure Very Long Tubes

The new Leapfrog feature allows you to measure any length of tube by measuring three or more magnetic cones, leaping the cones with the FARO arm, then measuring the cones again - then continuing measuring from where you left off before the leap.

A leap can occur at any point during any tube measurement.

Leapfrog moves are more accurate than using the "Move Tube" command because they rely on more precise conical seats.

Vtube-lasesr-1.91-leapfrog-button.png

Vtube-lasesr-1.91-leapfrog points before leap.png

Vtube-laser-1.91-faro magnetic cones.png

Vtube-laser-1.91-leapfrog illustration.png

Vtube-lasesr-1.91-leapfrog points after leap.png

Check.jpg NEW: Measurement Complete Dialog

This new measurement complete dialog gives you more choices than ever before. You can choose from any one of the available alignment methods in this dialog.

Vtube-laser-1.91-measurementcomplete dialog.png

Check.jpg NEW: FARO Calibration Dialogs Now Shows Either Inches or Millimeters

Previous versions showed all linear distance values in Millimeters. Some users prefer to view them in Inches, so now the dialogs will show either unit depending on the current unit setting in VTube-LASER.

Vtube-laser-1.91-farodialogs changing units closeup.png

Vtube-laser-1.91-farodialogs changing units.png

Check.jpg NEW: Click on the scanner control labels to load the scanner control

  • Now you can click on the scanner control lables to load the FARO Scanner control window.

Vtube-laser-1.91 click label load scanner control.png



Check.jpg NEW: Direct Communications with Eaton Leonard Premier, EL2000, and Ve-log Benders

  • Eaton Leonard Premier, EL2000, and Ve-log use an older current loop protocol that VTube can support with the appropriate electronics. (Benderlink Ethernet Module)

El premier 001.jpg



Check.jpg New: Comments Display in Dialog at Project Load

Comments now display in a dialog whenever a project is loaded.

Vtube-1.91-comment dialog.png

Check.jpg New: Pull Arm From Cradle Dialog

The Scanner Control settings are stored in VTube project files. In order for the scanner setup to be transferred into the arm, it is necessary to pull the arm from the cradle before the setup is transferred. VTube will ask you to move the arm when it is important.

Vtube-laser-1.91-pullarmfromcradle dialog.png

Check.jpg Enhanced: Project Batch Report Output

  • We added a second type of report per a customer spec.
  • The reports are now built to both comma delimted and tab delimited files.
  • The reports can be sent directly to Excel.

Vtube-1.90-project batch report output.png


Load the batch reporter in the Report menu of either STEP mode of LASER mode:

Vtube-1.90-project batch report button.png

This is a sample report file:

Vtube-1.90-project batch report file1.png

If the batch reporter finds files with 0 or negative length straights, then it will issue a WARNING at the end of the report log and create a second report file containing a list of all the project files with these lengths:

Vtube-1.90-project batch report file2.png

Check.jpg Other Changes

  • VTube will automatically set the wall thickness to 0.001 inches or 0.025 millimeters when the value is set to zero during VTube-STEP solid model centerline calculations.

  • Now you can press Enter to close the information dialog.

Other