Difference between revisions of "Setup VTube for Supravision Network Communication"

From ATTWiki
Jump to: navigation, search
(VTube-LASER Setup for Supravision Network Communications)
(VTube-LASER Setup for Supravision Network Communications)
Line 41: Line 41:
 
<table width=800>
 
<table width=800>
 
<tr valign=top>
 
<tr valign=top>
<td width=300>
+
<td width=400>
  
 
VTube-LASER uses a Benderlink grid to setup the communications protocol for each bender.  The grid is in Setup Options, Measure 2, Setup Benderlink Options menu.<br><br>
 
VTube-LASER uses a Benderlink grid to setup the communications protocol for each bender.  The grid is in Setup Options, Measure 2, Setup Benderlink Options menu.<br><br>
Line 47: Line 47:
 
In the Benderlink options menu, choose the bender to edit by selecting the cells in the bender row you want to setup.<br><br>
 
In the Benderlink options menu, choose the bender to edit by selecting the cells in the bender row you want to setup.<br><br>
  
* Set the bender name (this is for showing the bender name in the user interface only).
+
* Set the bender name (this is for showing the bender name in the user interface only).<br><br>
* Set the protocol by choosing Supravision Network.
+
* Set the protocol by choosing Supravision Network.<br><br>
* Set the NetPath where files will be shared.
+
* Set the NetPath where files will be shared.<br><br>
* Skip the ComPort setting because it has no application to this protocol.
+
* Skip the ComPort setting because it has no application to this protocol.<br><br>
* Set the timeout to from 5 to 10 seconds for most controls.  This will give the control a few seconds to respond to requests.
+
* Set the timeout to from 5 to 10 seconds for most controls.  This will give the control a few seconds to respond to requests.<br><br>
* Set the Part Name Match to Yes or No.  If the option is set to Yes, then a mismatched part name in the data will cause VTube-LASER to warn of a part name mismatch while receiving data.
+
* Set the Part Name Match to Yes or No.  If the option is set to Yes, then a mismatched part name in the data will cause VTube-LASER to warn of a part name mismatch while receiving data.<br><br>
* If the network location server has a fixed IP address, then the location can be pinged to prove that the network path is currently available before VTube attempts to save files in the network path.
+
* If the network location server has a fixed IP address, then the location can be pinged to prove that the network path is currently available before VTube attempts to save files in the network path.<br><br>
 
* Finally, set the number at the bender.  This allows any bender in any row to have any bender number.  Remember:  If all Supravision Network-based benders share the same network path, then each bender should be assigned a unique bender number.<br><br>
 
* Finally, set the number at the bender.  This allows any bender in any row to have any bender number.  Remember:  If all Supravision Network-based benders share the same network path, then each bender should be assigned a unique bender number.<br><br>
  

Revision as of 04:13, 9 January 2015

Vtube-laser logo 1.96.png Vtube-step logo 1.96.png



VTube-LASER and VTube-STEP can communicate with bender controls using the Supravision Network protocol.

VTube-STEP can SEND data to benders using the protocol. VTube-LASER can SEND and RECALL data to/from benders for full corrections loops.

Follow this guide to setup the VTube for communications with benders using the Supravision Network protocol.

Vtube 1.99 BendPro Connection.png


VTube-STEP Setup for Supravision Network Communications

Use the VTube-STEP Bender Output menu to setup and send new part data to a bender using Supravision Network protocol.

Go to the SV Network tab and choose the bender number and set the shared path where Supravision Network communications occurs.

  • The Supravision Network protocol uses a bender number (from 1 to 99) to indicate which bender should pickup and use the Supravision file that is being saved by VTube-STEP to the file path in the network box.

  • At the bender control, set the protocol to Supravision Network, set the bender number, set the path, and turn on communications if this is required.

Vtube-step 1.99 supravision network.png

VTube-LASER Setup for Supravision Network Communications

VTube-LASER uses a Benderlink grid to setup the communications protocol for each bender. The grid is in Setup Options, Measure 2, Setup Benderlink Options menu.

In the Benderlink options menu, choose the bender to edit by selecting the cells in the bender row you want to setup.

  • Set the bender name (this is for showing the bender name in the user interface only).

  • Set the protocol by choosing Supravision Network.

  • Set the NetPath where files will be shared.

  • Skip the ComPort setting because it has no application to this protocol.

  • Set the timeout to from 5 to 10 seconds for most controls. This will give the control a few seconds to respond to requests.

  • Set the Part Name Match to Yes or No. If the option is set to Yes, then a mismatched part name in the data will cause VTube-LASER to warn of a part name mismatch while receiving data.

  • If the network location server has a fixed IP address, then the location can be pinged to prove that the network path is currently available before VTube attempts to save files in the network path.

  • Finally, set the number at the bender. This allows any bender in any row to have any bender number. Remember: If all Supravision Network-based benders share the same network path, then each bender should be assigned a unique bender number.


Vtube setupbenderlinkoptions.png


Step 1: Move the mouse over the menu arrow to the right of the SolidWorks logo in the upper right corner.

Step 2: Move the mouse to Tools and down to Options - Click on Options

SolidWorks ToolsOptions Menu.png

Step 3: Click on Default Templates in the left column

SolidWorks ToolsOptions DefaultTemplatePaths Empty.png

Step 4: Choose the template files

Click on the ellipses buttons to setup the default path in these boxes. SolidWorks will suggest a file that already exists on the disk. Click on that file.

Fill in all three boxes with filenames.

SolidWorks ToolsOptions DefaultTemplatePaths.png

Click on OK. SolidWorks is ready to receive VTube commands.

Other Pages