Difference between revisions of "CNC Bender ProControl 10.0.6.2"

From ATTWiki
Jump to: navigation, search
 
(Configuration Reload)
Line 4: Line 4:
  
 
This feature is added to the Utility menu.  It allows for reloading the CNC Bender configuration without closing and reopening the CNC Bender software.
 
This feature is added to the Utility menu.  It allows for reloading the CNC Bender configuration without closing and reopening the CNC Bender software.
 +
 +
There are circumstances where changes to values in low-level configurations may normally need a reboot of the CNC Bender software.  Examples are changes to the Axis Configuration, Module configuration, and Processlist configration.  This new feature allows operators to reload the configuration without actually rebooting CNC Bender.
  
 
==Automatic Shutdown==
 
==Automatic Shutdown==

Revision as of 02:43, 19 March 2007

Date: March 15, 2007

Configuration Reload

This feature is added to the Utility menu. It allows for reloading the CNC Bender configuration without closing and reopening the CNC Bender software.

There are circumstances where changes to values in low-level configurations may normally need a reboot of the CNC Bender software. Examples are changes to the Axis Configuration, Module configuration, and Processlist configration. This new feature allows operators to reload the configuration without actually rebooting CNC Bender.

Automatic Shutdown

This feature is in replacement to the "Auto Heal" feature of earlier versions of CNC Bender.

New Automatic Shutdown when loss of TCP/IP connection. This allows for a new bender shutdown process:

1 - Press the E-stop.

2 - Power down the bender.

3 - CNC Bender will sense a loss of TCP/IP communication and propose a shutdown in 15 seconds. This shutdown can be overridden by the operator.

4 - The UPS inside the operator stations will shutdown