Difference between revisions of "CNC Bender ProControl 10.0.6.2"

From ATTWiki
Jump to: navigation, search
(NEW: Automatic Shutdown for CNC Bender and Windows)
(NEW PROCESS)
Line 26: Line 26:
  
 
3 - CNC Bender will sense a loss of TCP/IP communication and propose a shutdown in 15 seconds.  This shutdown can be overridden by the operator.
 
3 - CNC Bender will sense a loss of TCP/IP communication and propose a shutdown in 15 seconds.  This shutdown can be overridden by the operator.
 
+
[[image:Minuteman mn350.jpg|right|400px]]
 
4 - The CNC Bender UPS (inside the operator station) will initiate Windows shutdown after 60 seconds of loss of power.  (This has been verified for both Windows 2000 and Windows XP)
 
4 - The CNC Bender UPS (inside the operator station) will initiate Windows shutdown after 60 seconds of loss of power.  (This has been verified for both Windows 2000 and Windows XP)
  

Revision as of 17:20, 19 March 2007

Date: March 15, 2007

Contents

NEW: Configuration Reload

This feature is added to the Utility menu. It allows for reloading the CNC Bender configuration without closing and reopening the CNC Bender software.

There are circumstances where changes to values in low-level configurations may normally need a reboot of the CNC Bender software. Examples are changes to the Axis Configuration, Module configuration, and Processlist configration. This new feature allows operators to reload the configuration without actually rebooting CNC Bender.

NEW: Automatic Shutdown for CNC Bender and Windows

CNC Bender with Automatic Shutdown Active

A new Automatic Shutdown process is initiated when a loss of TCP/IP connection to any top hat module around the bender is disocvered. This allows for a much-improved and smoother bender shutdown process.

OLD PROCESS

The older process required that Windows be turned off using the Start menu. Then the operator opened the back of the operator station to switch the station be opened and the MinuteMan MN350 powered down.

Cncbender automaticshutdown dialog.jpg

NEW PROCESS

The new process is much easier...

1 - Press the E-stop.

2 - Power down the bender.

3 - CNC Bender will sense a loss of TCP/IP communication and propose a shutdown in 15 seconds. This shutdown can be overridden by the operator.

Minuteman mn350.jpg

4 - The CNC Bender UPS (inside the operator station) will initiate Windows shutdown after 60 seconds of loss of power. (This has been verified for both Windows 2000 and Windows XP)

5 - The CNC Bender UPS will power down 90 seconds after Windows was shutdown.



Note: This feature is in replacement to the "Auto Heal" feature introduced in version 10.0.6.0 of CNC Bender.