Difference between revisions of "VTube Communication with YLM Benders"
(→Basic Idea for Sending Data) |
(→Basic Idea for Sending Data) |
||
Line 28: | Line 28: | ||
</table> | </table> | ||
− | ==Basic | + | ==Basic Principle for Sending Data to YLM== |
<table> | <table> | ||
<tr valign=top> | <tr valign=top> | ||
Line 34: | Line 34: | ||
The process works like this:<br><br> | The process works like this:<br><br> | ||
− | # - VTube: Measure a part. | + | # - VTube: Measure a part.<br><br> |
− | # - VTube: Save the measured part data to a Supravison file. | + | # - VTube: Save the measured part data to a Supravison file.<br><br> |
− | # - YLM Control: Load the same Supravision file into the control using the CORRECTION button. | + | # - YLM Control: Load the same Supravision file into the control using the CORRECTION button.<br><br></td> |
− | </td> | + | |
<td width=300> | <td width=300> | ||
Revision as of 18:17, 11 December 2015
VTube-STEP and VTube-LASER Support for YLM Benders
VTube-STEP can export Supravision data to YLM benders. |
Basic Principle for Sending Data to YLM
The process works like this:
|
Using VTube-LASER to send NEW MASTER Data to YLM Benders
The connection the bender is made with standard network connection, and a shared folder location between the VTube computer and the operator station computer. For a NEW TUBE, the YLM takes in VTube MASTER Supravision LRA data in a Supravision file.
|
Follow these steps at VTube-LASER to Send a NEW TUBE SETUP to a YLM Bender
STEP 1 |
Follow these steps at the YLM CONTROL to import the MASTER data from VTube-LASER
STEP 1 |
|
STEP 2 |
|
STEP 3 |
|
STEP 4 |
|
STEP 5 |
|
STEP 6 |
VTube-LASER CORRECTION Steps for YLM Benders
The connection the bender is made with standard network connection, and a shared folder location between the VTube computer and the operator station computer.
Handling Opposite CorrectionsThere are two ways to overcome the opposite correction problem: 1 - Use a special INVERSION checkbox in the VTube Supravision Export menu. Only use this inversion switch when sending measured data for correction. 2 - Have the YLM technician change the internal low level setting in the YLM control that makes the correction be apply in the normal way. |
Follow these steps at VTube-LASER to Correct a YLM Bender
STEP 1 |
|
STEP 2 |
|
STEP 3 |
Follow these steps at the YLM CONTROL to import the measured data from VTube-LASER
STEP 1 |
|
STEP 2 |
|
STEP 4 |
Shutdown to Edit the Windows Setup
To shutdown the YLM software to configure Windows settings:
- Press the Shutdown button.
- Press "NO" for shutdown.
- Type "12345" and OK in the numeric keypad.
- YLM will close without shutting down the computer.
Other Pages
- See VTube-LASER
- See VTube-STEP
- See YLM for information on the YLM benders