Difference between revisions of "Recommended VTube-LASER Laser Scanner Settings"
From ATTWiki
(→STEP 5) |
(→STEP 1) |
||
Line 26: | Line 26: | ||
===STEP 1=== | ===STEP 1=== | ||
In VTube-LASER window click on '''Scanner Algorithm''' label above the viewport window.<br><br> | In VTube-LASER window click on '''Scanner Algorithm''' label above the viewport window.<br><br> | ||
+ | This loads the '''FARO Laser Line Probe Control''' window.<br><br> | ||
The alternative way to get into the FARO LLP Scanner window is to click on '''Measure Setup''' in the '''Navigation Pane''' > '''Arm tab''' > '''Scanner Control''' button.</td> | The alternative way to get into the FARO LLP Scanner window is to click on '''Measure Setup''' in the '''Navigation Pane''' > '''Arm tab''' > '''Scanner Control''' button.</td> | ||
<td> | <td> |
Revision as of 01:40, 26 December 2015
|
Ideal Setup for the HD Version 6 Scanner in VTube-LASER
The HD blue line scanner has significantly increased capabilities that cause us to revise recommendations in FARO scanner setup when compared to earlier scanners. These settings work very well in VTube-LASER with the HD scanner.
VTube-LASER be connected to a FARO arm to perform these steps.
STEP 1In VTube-LASER window click on Scanner Algorithm label above the viewport window. |
|
STEP 2Set the Scan Rate to 1/1.
Set the Scan Density to 1/16
|
|
STEP 3For most materials set the Algorithm to Automatic - Normal. |
|
STEP 4Uncheck the Reflection Filter option.
|
|
STEP 5Click on the OK button to exit the FARO Laser Line Probe window. |
Other Pages
- Back to the VTube-LASER page