Difference between revisions of "VTube-LASER to Eaton Leonard Premier Communications Tutorial"
(→How to Send a New Part from VTube-LASER to a Premier) |
(→How to Send a New Part from VTube-LASER to a Premier) |
||
Line 74: | Line 74: | ||
</table> | </table> | ||
− | =How to Send a | + | =How to Send a NEW Part from VTube-LASER to a Premier= |
<table> | <table> | ||
<tr> | <tr> | ||
Line 95: | Line 95: | ||
</table> | </table> | ||
+ | |||
+ | |||
+ | =How to CORRECT an Existing Part from VTube-LASER to a Premier= | ||
+ | <table> | ||
+ | <tr> | ||
+ | <td width=400 valign=top> | ||
+ | |||
+ | # Enter the Bender Setup window. Set the bender number (at the top of the window). The protocol should show Eaton Leonard. The bender image show show an Eaton Leonard bender.<br><br> | ||
+ | # In the '''Bidirectional Communications''' expanding menu on the right, press '''RECALL'''. (Be sure that the bender is ready for communication. See the "Premier VECTOR 1 Menu With Communications Active" section above.) This action will update the BLUE columns and also the bender data in the Eaton Leonard Setup window.<br><br> | ||
+ | [[image:vtl Eaton Leonard Setup New Part AUTO SEND.png|400px]] | ||
+ | </td> | ||
+ | <td valign=top> | ||
+ | [[image:vtl Eaton Leonard copy LRA master to bender setup.png|500px]]<br> | ||
+ | [[image:vtl Eaton Leonard Setup 345 pointers.png|500px]]<br> | ||
+ | [[image:vtl Eaton Leonard Setup New Part Pointer 6 to AUTO SEND.png|500px]] | ||
+ | </td> | ||
+ | </tr> | ||
+ | |||
+ | </table> | ||
+ | |||
+ | |||
==Other Pages== | ==Other Pages== |
Revision as of 16:47, 2 December 2016
VTube-LASER uses the legacy Eaton Leonard Current Loop protocol to communicate with Premier controls. The protocol requires that an RS-232 signal be converted to Current Loop, then sent to the bender. |
Contents |
Communications Setup at the EL Premier Control
Communications between VTube-LASER and the Premier is very easy to do because it's robust and also very intuitive.
About The VECTOR 1 Menu
All communications from the PREMIER control occurs in the VECTOR 1 screen shown here. |
Premier Communications Active
To put the Premier in communications mode, make the REQUEST TRANSFER box active (green) like is shown here. The WAITING field will be highlighted. CHECK 1 - CORRECT MODE IS ACTIVE |
How to Edit Premier Control Data Inside VTube-LASER
VTube-LASER (v2.7 or higher) will allow for the complete setup of all bender and setup data that can be stored in a Premier control in the VTube-LASER Eaton Leonard Setup window. (Note: Even though this tutorial covers mainly the Premier control, this data is also compatible with older EL-2000 and Velog controls.) Click on the image on the right to see a closeup of the Eaton Leonard Setup window. You can load this window from inside the VTube-LASER Bender Setup window. |
How to Send a NEW Part from VTube-LASER to a Premier
|
How to CORRECT an Existing Part from VTube-LASER to a Premier
|
Other Pages
- See VTube-LASER to Premier, EL2000, Velog Data Transfer
- Back to the Benderlink Ethernet Module Page
- Back to VTube-LASER
- Back to Eaton Leonard