Difference between revisions of "VTube Communication for BLM VGP3D"

From ATTWiki
Jump to: navigation, search
(How to SEND CORRECTION Data to the BLM Control from VTube-LASER)
(RECALL Warning Boxes)
Line 160: Line 160:
 
[[image:VTL BLM RECALL increase Bend Count.png|600px]]<br><br>
 
[[image:VTL BLM RECALL increase Bend Count.png|600px]]<br><br>
 
[[image:VTL BLM RECALL use incoming part number.png|600px]]<br><br>
 
[[image:VTL BLM RECALL use incoming part number.png|600px]]<br><br>
 +
</td>
 +
</tr>
 +
</table>
 +
 +
<br><br>
 +
 +
 +
===AFTER RECALL===
 +
<table cellpadding=10>
 +
<tr valign=top>
 +
<td width=300>
 +
After the RECALL, the Blue Columns will show the data that is programmed in the BLM control.
 +
</td>
 +
<td width=400>
 +
[[image:VTL BLM RECALL Complete.png|600px]]<br><br>
 
</td>
 
</td>
 
</tr>
 
</tr>

Revision as of 21:29, 23 June 2017

Blm logo.png Blm elect80.png

About this Page

This page describes the setup and use of the VTube to BLM communications.


The Basics of How It Works

  • VTube-LASER RECALLS, MODIFIES, and SAVES data directly in ".BLM" files. A communications link can be setup through a standard Windows network connection.

  • The communication is bi-directional to and from the bender. It is possible to RECALL data from the BLM using the .BLM file format.

  • The data that is included in the BLM file that the AMOB can read is the BENDER data (Xc axis, Yc Axis, Zc Axis). The data also includes the diameter and the cut length.

  • The protocol does not send the RADIUS data. Sending radius data causes the VGP-3D to reset the tools and rebuild all custom commands - so VTube-LASER avoids sending this data.

Blm vgp3d screen.png

Communications Setup at the BLM Bender

  • Connect the BLM bender to the network using a standard Ethernet cable.

  • Setup a shared network location either in the BLM windows control or in a network path on your network.

  • If you share a folder on the BLM control, then create a user with a username and password that can be used to login to the computer from the VTube-LASER computer.

Setup Benderlink at VTube-STEP or VTube-LASER

Entering Benderlink Setup

  1. Enter the VTube System Options menu.

  2. Enter the Measure 2 tab menu.

  3. Enter the Setup Benderlink Network menu.

VTube System Options Benderlink Network Button.png

Setup the Benderlink Network Grid for the BLM Bender

  1. Choose an unused row in the grid for a new BLM bender setup. (Click on the image at the right to see a zoomed image.)

  2. Assign a bender name that will help operators identify what this bender is. This text will be displayed at the top of the Bender Setup menu.

  3. Set the protocol to BLM Data.

  4. Enter the path to the shared drive or folder in the NetPath field. Use the same location as the BLM setup. VTube accepts UNC names as well as regular paths with drive letters.

  5. Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)

  6. Most BLM benders handle Positive rotations as Clockwise, so you will probably need to enter "YES" for this option (so that the rotations are not corrected in the wrong direction).

  7. Press Close to save the settings. VTube will save these values to a persistent configuration file that will not change unless you change them in this grid.

Vtube-laser benderlink blm setup.png

How to SEND CORRECTION Data to the BLM Control from VTube-LASER

After Bending the Tube

Bend a tube then measure it with VTube-LASER.

Measure the tube with VTube-LASER

Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.

In the VTube-LASER screen shot, you see the actual result of the first tube not qualifying in shape. The red cells in the tangent point grid on the lower left show that the measured tube centerline is out-of-tolerance.

Vtube-laser v2.7 soco part measure.png

Vtube-laser v2.7 soco out of tolerance.png


Correct the BLM with VTube-LASER - Enter BENDER SETUP

Follow these steps in the VTube-LASER:

Press the "BENDER SETUP button in the Navigation Pane.

Vtube-laser 2.7 bendersetup button navigationpane.png

INITIAL RECALL Setup of Bender Setup Window

The first time in this window for a new part will require these steps before you can correct the BLM bender. These steps assume that you have programmed a part in the bender, and that you have measured and aligned a part.

STEP 1 - Set the correct bender number at the top of the window. The BLM bender should display if you have already setup the bender protocol in the Benderlink grid.


STEP 2 - Click on the "Bidirectional Communication" button.


STEP 3 - Click on the "RECALL LRA from BENDER" button.


STEP 4 - Select the BLM file to open.

VTL Initial RECALL from BLM.png
VTL Initial Recall from BLM with open dialog.png


RECALL Warning Boxes

VTube-LASER will probably warn you that the incoming data count and part number does not match what is in VTube-LASER.

Allow the process to increase the bend count, and accept the incoming part number.

VTL BLM RECALL increase Bend Count.png

VTL BLM RECALL use incoming part number.png




AFTER RECALL

After the RECALL, the Blue Columns will show the data that is programmed in the BLM control.

VTL BLM RECALL Complete.png



Send the Corrections to the BLM File


Save the Correction data to the file for the AMOB to import.

STEP 1 - Click on Bidirectional Communication

STEP 2 - Click on AUTO SEND.

STEP 3 - Save the new VTL file to the network location.

VTL Bender Setup AMOB Correction.png




Import the Correction Data at the AMOB Control


Save the Correction data to the file for the AMOB to import.

STEP 1 - Enter the Program Machine Configuration menu.

STEP 2 - Press the FARO (or it may be "VTube") button

STEP 3 - Open the VTL file.

Amob program machine configuration press FARO.png

AMOB Control Bender Data Updated


The bender data will be updated with the new values.

Bend the corrected part.

AMOB bender data screen.png

Synchronizing the VTube-LASER and AMOB Data Before Corrections

It is critical to be sure the blue columns contain the same data that the AMOB X Axis, Y Axis, Z axis values have before correction is applied.

To make the data the value the same for the next correction, you can press the bottom button in the Bidirectional Communications menu on the right. Be sure you do this BEFORE you measure the next corrected part.

The reason for this step is because the AMOB does not allow VTube to RECALL data in order to update the BLUE columns for the next correction. So this process must be performed manually.

The data in the blue and the orange columns will now be identical. You can exit this window and measure the next corrected part.

Combine Adjusted back into LRA then CLEAR Adjusted.png

Adjusted data combined into blue columns.png

Other Pages