Difference between revisions of "Why VTube-LASER Reduces Data to Centerlines"
(Created page with "<table width= 400> <tr cellpadding=10> <td width=200> * Why does VTube-LASER reduce data to centerlines?<br><br> </td> <td width=200> image:VTube-LASER_AssemblyOverModel.png...") |
Revision as of 15:42, 21 June 2022
|
Answer
VTube-LASER always automatically reduces each straight scanned to a centerline and then compares measured centerline data with the master. This has been the method used in the tube-fabrication industry for decades because fabricated tube shapes are always defined using centerline geometry. So, the goal of VTube-LASER is to always reduce a measured profile, whether it be cylinder or rectangular, to a centerline for qualification and bender data calculation.
Before it reduces the straight to a centerline, VTube-LASER always calculates important metrics that help the user gauge how well the surface data fits to the centerline. Not only does it qualify each cylinder straight fit to a centerline, but the process always gives a calculated diameter and the surface profile of the scan.