Difference between revisions of "CNC Bender LiteControl 10.0.6.0"

From ATTWiki
Jump to: navigation, search
([direct_axis_jog])
([direct_axis_jog])
Line 35: Line 35:
  
 
#Each parameter is separated by commas.
 
#Each parameter is separated by commas.
#The first parameter is the name of the module, the second parameter is the axis of the module (1 or 2), and the final parameter indicates direction.
+
#PARAMETER 1: The first parameter is the name of the module
#"1" means positive jog.
+
#PARAMETER 2: The second parameter is the axis of the module (1 or 2)
#"-1" means negative jog.
+
#PARAMETER 3: The third parameter indicates direction. "1" means positive jog. "-1" means negative jog.
 
<br>
 
<br>
  

Revision as of 00:21, 6 September 2008

Cncbender litcontrol logo.jpg

Operatorstation model.jpg

Contents


This is change to an older version of CNC Bender LiteControl. It is intended to update customers with older 800 x 600 screen operator stations.

Check.jpg New: BUILT IN SEAM DETECT LOGIC

The new feature includes a new Seam Detect option in the PreBend option:
Seamdetect.jpg

Enable this option to include seam detection logic in the process list.

If enabled, the new commands for seam detection are added to the processlist between the chuck close and the run button logic. This is a sample of what is inserted:

Seamdetect processlist.jpg



The new "seam_detect.cncprocesslist" is a secondary multitasking processlist that is configurable to work with the application.


Check.jpg New: Internal Commands

Two new internal commands for process lists are now included: [direct_axis_jog] and [direct_axis_jog_halt]

[direct_axis_jog]

This processlist internal command will allow the process to direct-jog and axis as if a user had pressed a jog button. Configure the command by including parameters like this:

[direct_axis_jog] servo_controller_module_1, 2, 1
  1. Each parameter is separated by commas.
  2. PARAMETER 1: The first parameter is the name of the module
  3. PARAMETER 2: The second parameter is the axis of the module (1 or 2)
  4. PARAMETER 3: The third parameter indicates direction. "1" means positive jog. "-1" means negative jog.


Other Pages