Difference between revisions of "Pro/ENGINEER"
(→Known Problems for Pro/E with Calculation of Centerline Data) |
|||
Line 4: | Line 4: | ||
[[FIF Translator]] can convert convert data from Pro/E into data that is compatible with most benders in the industry. | [[FIF Translator]] can convert convert data from Pro/E into data that is compatible with most benders in the industry. | ||
+ | |||
+ | <br><br> | ||
+ | |||
==Known Problems for Pro/E with Calculation of Centerline Data== | ==Known Problems for Pro/E with Calculation of Centerline Data== | ||
Line 13: | Line 16: | ||
In these cases, the YBC or LRA bender data can still be extracted from the FIF file since this data is correct. For example [[Benderlink for Chiyoda]] and [[Benderlink for KEINS]] allow operators to choose which set of data, the XYZ centerline data or the YBC/LRA bender data, is imported. | In these cases, the YBC or LRA bender data can still be extracted from the FIF file since this data is correct. For example [[Benderlink for Chiyoda]] and [[Benderlink for KEINS]] allow operators to choose which set of data, the XYZ centerline data or the YBC/LRA bender data, is imported. | ||
− | + | <br><br> | |
+ | |||
+ | ==Other== | ||
See the [http://en.wikipedia.org/wiki/Pro/ENGINEER Wikipedia site for Pro/ENGINEER] | See the [http://en.wikipedia.org/wiki/Pro/ENGINEER Wikipedia site for Pro/ENGINEER] | ||
<br><br> | <br><br> | ||
See the [http://www.ptc.com/appserver/mkt/products/home.jsp?&k=5261 PTC Web Site Page for Piping and Cabling] | See the [http://www.ptc.com/appserver/mkt/products/home.jsp?&k=5261 PTC Web Site Page for Piping and Cabling] |
Revision as of 12:21, 30 October 2008
With the Piping and Cabling Extension, Pro/E can output FIF files.
FIF Translator can convert convert data from Pro/E into data that is compatible with most benders in the industry.
Known Problems for Pro/E with Calculation of Centerline Data
We have discovered that when Pro/E encounters a 180 degree bend that it incorrectly calculates the centerline XYZ coordinates for the FIF data that it builds. Rather than attempting to build two points for the 180 degree bend, it shows 1 point for that bend. The resulting centerline tube is usually nothing like the actual tube shape.
This is a normal problem when developers of tube fabrication software forget to test special cases - like 180 degree bends - in their algorithms.
In these cases, the YBC or LRA bender data can still be extracted from the FIF file since this data is correct. For example Benderlink for Chiyoda and Benderlink for KEINS allow operators to choose which set of data, the XYZ centerline data or the YBC/LRA bender data, is imported.
Other
See the Wikipedia site for Pro/ENGINEER
See the PTC Web Site Page for Piping and Cabling