"Machine Lube" Section

The settings in this file are separated by sections with section names in square brackets. This is an example:

[Machine Lube]
Machine Lube Duration=5000
Lube Machine At Bend Count=100
Pulse Machine Lube Pump=1
Watch For Machine Lube Complete Input=0

The four values above control the machine lube features in CNC Bender.

Value 1: "Machine Lube Duration"

Value 2: "Lube Machine At Bend Count"

Value 3: "Pulse Machine Lube Pump"

Value 4: "Watch For Machine Lube Complete Input"