VTube Communication for BLM VGP3D

From ATTWiki
Revision as of 17:58, 18 January 2019 by Mcone (Talk | contribs)

Jump to: navigation, search

Vtl2blm.png

Blm elect80.png

About this Page

This page describes the setup and use of the VTube to BLM communications.

Contents


TWO PROTCOLS

As of early 2019, VTube-LASER supports one of two protocols for connecting to the BLM VGP-3D control.

BLM CMM (NEWER)

  • The BLM CMM protocol was introduced in VTube-LASER version 2.9.18.
  • It is the preferred protocol because it is very easy to use and does not interfer with custom commands inside the BLM VGP-3D control.
  • BLM may charge for this protocol to be switched on.
  • The BLM catalog number is "SW0842".
  • This protocol can send centerline UVW, bender XcYcZc, part number, diameter, wall thickness, cut length, and radii values.

BLM DATA

  • The older legacy control is referred to as BLM DATA. Older versions of VTube-LASER have this protocol.
  • It can read and write native .BLM files for setup and correction.
  • This is the protocol that you can use on older controls that do not have the BLM CMM control.
  • This protocol does not send radii. (Sending radii data causes VGP-3D to reset the tool page information.)
  • The steps to use this protocol are more complicated than the BLM CMM protocol.

BLM control.png



Communications Setup at the BLM Bender for Both Protocols

This network setup is similar for both protocols.

  • Connect the BLM bender to the network.

  • Connect the VTube-LASER computer to the network.

  • Setup a shared network location either in the BLM windows control or in a network path on your network.

  • If you share a folder on the BLM control, then create a user with a username and password that can be used to login to the computer from the VTube-LASER computer.

  • If you are using the BLM CMM protocol, then on the VGP-3D you must map to the shared network drive. The drive letter for the map must be Z:\. (This is a fixed letter inside VGP-3D logic.)

Ethernet cable orange.png

NEWER BLM CMM Protocol Section

About How BLM CMM Protocol Works

  • VTube-LASER RECALLS, MODIFIES, and SAVES data directly in "CMM.txt" files that the VGP-3D software can export and import. Per the instructions above, a communications link can be setup through a standard Windows network connection.

  • The communication is bi-directional to and from the bender. It is possible to RECALL data from the BLM using the CMM.txt file format.

  • The data that is included in the BLM CMM.txt file that the BLM can read/write is the UVW data (the tube centerline data), the BENDER data (Xc axis, Yc Axis, Zc Axis). The data also includes the diameter, wall, cut length, and all radii.

Blm vgp3d screen xcyczc.png



OLDER LEGACY BLM DATA Protocol Section

How BLM DATA Protocol Works

  • VTube-LASER RECALLS, MODIFIES, and SAVES data directly in ".BLM" files. A communications link can be setup through a standard Windows network connection.

  • The communication is bi-directional to and from the bender. It is possible to RECALL data from the BLM using the .BLM file format.

  • The data that is included in the BLM file that the BLM can read is the BENDER data (Xc axis, Yc Axis, Zc Axis). The data also includes the diameter and the cut length.

  • The protocol does not send the RADIUS data. Sending radius data causes the VGP3D to reset the tools and rebuild all custom commands - so VTube-LASER avoids sending this data.

Blm vgp3d screen.png



Setup Benderlink at VTube-STEP or VTube-LASER with the BLM DATA Protocol

Entering Benderlink Setup

  1. Enter the VTube System Options menu.

  2. Enter the Measure 2 tab menu.

  3. Enter the Setup Benderlink Network menu.

VTube System Options Benderlink Network Button.png

Setup the Benderlink Network Grid for the BLM Bender

  1. Choose an unused row in the grid for a new BLM bender setup. (Click on the image at the right to see a zoomed image.)

  2. Assign a bender name that will help operators identify what this bender is. This text will be displayed at the top of the Bender Setup menu.

  3. Set the protocol to BLM Data.

  4. Enter the path to the shared drive or folder in the NetPath field. Use the same location as the BLM setup. VTube accepts UNC names as well as regular paths with drive letters.

  5. Enter the IP address in the PING IP ADDRESS field if it is a fixed field. (This is not required. It allows VTube to ping the address to see if the network location is active before trying to open communications.)

  6. Most BLM benders handle Positive rotations as Clockwise, so you will probably need to enter "YES" for this option (so that the rotations are not corrected in the wrong direction).

  7. Press Close to save the settings. VTube will save these values to a persistent configuration file that will not change unless you change them in this grid.

Vtube-laser benderlink blm setup.png



How to SEND CORRECTION Data to the BLM Control from VTube-LASER

After Bending the Tube

Bend a tube then measure it with VTube-LASER.

Measure the tube with VTube-LASER

Measure and align the tube to determine if it qualifies by falling within the envelope tolerance for the tube shape.

In the VTube-LASER screen shot, you see the actual result of the first tube not qualifying in shape. The red cells in the tangent point grid on the lower left show that the measured tube centerline is out-of-tolerance.

Vtube-laser v2.7 soco part measure.png

Vtube-laser v2.7 soco out of tolerance.png


Correct the BLM with VTube-LASER - Enter BENDER SETUP

Follow these steps in the VTube-LASER:

Press the "BENDER SETUP button in the Navigation Pane.

Vtube-laser 2.7 bendersetup button navigationpane.png

INITIAL RECALL Setup of Bender Setup Window

The first time in this window for a new part will require these steps before you can correct the BLM bender. These steps assume that you have programmed a part in the bender, and that you have measured and aligned a part.

STEP 1 - Set the correct bender number at the top of the window. The BLM bender should display if you have already setup the bender protocol in the Benderlink grid.


STEP 2 - Click on the "Bidirectional Communication" button.


STEP 3 - Click on the "RECALL LRA from BENDER" button.


STEP 4 - Select the BLM file to open.

VTL Initial RECALL from BLM.png
VTL Initial Recall from BLM with open dialog.png


RECALL Warning Boxes

VTube-LASER will probably warn you that the incoming data count and part number does not match what is in VTube-LASER.

  • It is very important that you allow the incoming bender data to increase the bend count to whatever is at the bender.

  • If you want the Part Number at the bender to be left untouched, then just accept the incoming part number and use it for transfer from this point forward.

VTL BLM RECALL increase Bend Count.png

VTL BLM RECALL use incoming part number.png



THE BLUE COLUMNS SHOULD MATCH THE BLM XYZc DATA AFTER THE RECALL

After the RECALL, the blue columns should show the data that is programmed in the BLM control.

This ensures that corrections are being made to the correct foundational data. If the blue column data does not match the bender at correction time, then it is probable that the bender will not be corrected properly.

VTL BLM RECALL Complete.png



MERGE THE CORRECTIONS INTO THE BLM FILE

MERGE and SAVE the Correction data to the file for the BLM to import by pressing AUTO SEND BENDER CORRECTIONS.

STEP 1 - Click on Bidirectional Communication

STEP 2 - Click on AUTO SEND BENDER CORRECTIONS.



This will change the contents of the BLM file to the values in the ORANGE cells.

VTube also makes a backup of the current setup to a .blm$ file in case you want to undo that last correction.

VTL BLM Send Send Correction.png



THESE ARE THE DIALOGS INSIDE THE AUTO SEND FEATURE

DIALOG 1 - The first dialog explains how communications works. This is for any user that needs to be reminded of how the merge process works.

DIALOG 2 - In the SAVE dialog, select the BLM file to merge data into, then press Save.

DIALOG 3 - VTube will show a timed message about the data merge.

VTL BLM Send Correction Explanation Dialog.png

VTL BLM Send Correction with Open Dialog.png

VTL BLM Send Correction with Timed Message.png



AFTER CORRECTION - LOAD THE NEW BLM FILE INTO THE VGP-3D SOFTWARE AT THE BLM CONTROL

Load the BLM data VTube just saved into the VGP-3D software.

BLM control.png

VTL BLM VGP-3D XYZc Screen.png

CRITICAL STEP: Recalculate the BLM Memory Following These Easy Steps

This next step is CRITICAL for proper operation of the BLM software. Without it, the new data will not be sent to the PLC.

  • Touch any value on the XYZc grid.

  • Without changing the value, press the Enter button (the pen button).

This will recalculate the internal BLM data.

IF YOU DO NOT TAKE THIS STEP, THEN THE XYZc VALUES ON THE SCREEN WILL NOT BE THE VALUES IN THE POINT TABLE THAT CONTROLS THE BENDER MOTION.

VTL BLM VGP-3D XYZc Screen Enter Change.png

SIMULATE and RUN


  • Run the simulator with the new data.

  • Bend the corrected part.

  • Take the part back to VTube-LASER to measure it again for qualification.

Blm elect80.png

THE IMPORTANCE OF NOT RENAMING THE BLM FILE DURING CORRECTIONS

In order to retain custom moves already setup in VGP3D, it is important that you DO NOT CHANGE the .BLM filename during corrections.


Why?

The .BLM file that VTube-LASER modifies is accompanied by a point table file with the same filename but with a different filename extension of .OUT.

For example, on the BLM control, if there is a file "12345678.BLM" and you have bent the part, then there is a file "12345678.OUT" which represents the point table.

The .OUT file can contain custom lines that an operator programmed into the BLM for avoidance moves. If the .OUT file exists, then the SIMULATION CONTROL buttons (shown on the right) will be colored blue or green. If the .OUT file does not exist, then they will be grey - and the point table will need to be rebuilt.

Vgp3d simulation controls.png