HEXAGON Absolute Arm Feature Packs or Control Packs

From ATTWiki
Revision as of 17:59, 3 October 2022 by Mcone (Talk | contribs)

Jump to: navigation, search

Information about HEXAGON Absolute Arm Hardware



VTube-LASER HEXAGONRDS with AS1 Scanner.png


See also RDS Versions for ROMER Scanners

Contents


Cables Between Arms and Computers

NEWER ARMS: Two Cables Per ROMER Arm

The newer ROMER scanners communicate with the computer using:

  1. A TCP/IP connection using an Ethernet cable is used to give feedback from the SCANNER.

  2. A power cable

You will need one open Ethernet port and one open USB port for the ROMER arm connection.

OLDER ARMS: Three Cables Per ROMER Arm

The older ROMER scanners communicate using:

  1. A TCP/IP connection using an Ethernet cable is used to give feedback from the SCANNER.

  2. A USB cable connection is used to send the ball probe position.

  3. A power cable

You will need one open Ethernet port and one open USB port for the ROMER arm connection.

ROMER cable computer end.png

Arm Feature Packs or Control Packs

7-Series Arm Feature Pack

This is the ROMER Scanning Pack that is attached to the back base of the 7-series arms. It includes ports for power, USB, and Ethernet.

If you are using a laser scanner, then the Ethernet cable must be connected and setup with the proper IP address.

ROMER Scanning Pack - 7 series.png ROMER Scanning Pack - 7 series with arm.png

Original 8-Series Arm Control Pack

This is the HEXAGON Absolute Arm Control Pack that is attached to the back base of the 8-series arms when the 8-series was originally released. It includes ports for power, USB, and Ethernet.

If you are using a laser scanner, then the Ethernet cable must be connected. These control packs will automatically serve an IP address to your computer.

ROMER Scanning Pack - 8 series front.png ROMER Scanning Pack - 8 series back.png

2021 (Newer) CP-Series Arm Control Pack

This is the HEXAGON Absolute Arm Control Pack that is attached to the back base of the newer 8-series arms. This pack is highly recommended for its simplicity compared to older packs.

It includes two ports. One is for power and the other is Ethernet. (There is no more USB port.) This was probably a customer-requested improvement because the competing FARO models only required a single USB cable.

HEXAGON recommends that it be connected through the included DEXLAN USB to Ethernet adapter - which seems to work great on our demo arms.

So, to the best our knowledge, this is the only scan arm that uses an Ethernet cable to communicate both probe and scanner data to the computer (as of October 2022).

These control packs automatically serve an IP address to your computer.

The CP-C are cabled control packs.
The CP-W are wireless control packs.

The CP in the picture is a CP-C.

ROMER Scanning Pack - CP series front.png ROMER Scanning Pack - CP series back.png





Other Pages