CNC Bender v12-20111222

From ATTWiki
Revision as of 04:36, 24 December 2011 by Mcone (Talk | contribs)

Jump to: navigation, search

v12-20111222

Cncv12procontrol withteachmode.jpg

Check.jpg NEW - Servo-controlled PRESSURE DIE Motion

Manual page PD axis.jpg
Manual page PD axis closeup.jpg

  • Servo-controlled pressure die positioning is much more accurate and the motion is smoother.

  • This feature is especially useful for extreme accuracy during part capture. Parts can be accurately captured by the pressure die during PREBEND (Load), BENDING, and POSTBENDING (Unloading).



Pd servo encoder.jpg

Check.jpg NEW - Options for PD Servo Motion

PreBend Options: PD Load Capture Position

  • This feature allows you to move the pressure die to a position close to the bend die for load-capture.

Pd servo load capture.jpg

Overall Options: PD Jog Position After Bends

  • This feature allows you to open the pressure die slightly after a bend to relieve pressure before a mandrel pull.

Pd servo jog position after bends.jpg

Bending Options: PD Servo Retract Position

  • This feature allows you to partially retract the pressure die during Multi-Bending and immediately after a bend.

Pd servo retract postion.jpg

PostBending Options: PD Unload Capture Position

  • This feature allows you to partially retract the pressure die immediately after the last bend for unloading.

Pd servo unload capture.jpg



Check.jpg Other

  • A new Low Level PD Mode option allows the Pressure Die to be treated as a standard output actuator or a servo axis.

  • A new Low Level PD Servo Fixed Close Position option is added that controls the single fixed position of a closed pressure die when the PD Mode is set to Servo Fixed Position.

  • Pressure Die COMDEFs were added:
    • PD Servo Absolute
    • PD Servo Incremental Positive
    • PD Servo And Clamp Output And PDA Output Home
    • PD Servo Absolute And PDA Output Home
    • PD Servo Absolute And Clamp Output Home
    • PD Servo Find Home
    • PD Servo Reset Position
    • PD Servo Absolute and PDA Servo Absolute
    • PD Servo Absolute And PDA Output Home

  • COMDEF Names Changed
    • PressureDieBoostToHome to "PD Output PDA Output Home"
    • Pressure Die and PDA Motion Home to "PD Output and PDA Servo Home"

  • New help files were added:
    • PDMode.rtf
    • PDServoFixedClosedPosition.rtf
    • PDServoLoadCapturePosition.rtf
    • PDServoRetractPosition.rtf
    • PDServoUnloadCapturePosition.rtf


Other Pages