CNC Bender v12-20120728

From ATTWiki
Revision as of 17:35, 28 July 2012 by Mcone (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

v12-20120728

Cncv12procontrol withteachmode.jpg


Check.jpg Radius Level Shift Command Names Simplified

  • The command names for the radius level shifting were often confusing when moving from HEAD shifters to CARRIAGE shifters. For example, on a head shift machine, AllUp meant radius 1. On carriage shift machine, AllUp meant the top radius (2 or 3).


  • This ambiguity is cleared up by naming the directional valve positions by RADIUS LEVEL number, rather than "UP" or "DOWN".


  • These are the new DEFAULT command names to use:
    • Shift to Radius Level 1
    • Shift to Radius Level 2
    • Shift to Radius Level 3
    • Shift to Radius Level 4
    • Shift to Radius Level 2 From 1
    • Shift to Radius Level 2 From 3
    • Shift to Radius Level 3 From 2
    • Shift to Radius Level 3 From 4

Check.jpg Radius Level Shift Command Names Can Be Changed

  • The radius level COMDEF names can be configured to custom names in the Low Level COMDEF Names Cross Reference menu.

400


Check.jpg Changed the Name of "Low Level Options List" to "Setup Options List"

  • The Options List tab has been renamed.