Benderlink for MiiC

From ATTWiki
Revision as of 18:33, 21 September 2006 by Jesralian (Talk | contribs)

(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

Contents

Benderlink for MiiC Laservision Support

Laservision is an Eaton Leonard measuring center. Benderlink for MiiC now supports LASERVISION for communications to MiiC benders using the MiiC BSC protocol.

Benderlink for MiiC Import Formats

Import File Formats

  1. Benderlink for MiiC (Advanced Tubular format)
  2. Supravision File (Romer/Cimcore format)

About SV Import Format

  • Benderlink for MiiC allows for import of any Supravision file.

What About XYZ and Bender Daya in SV?

  • YES to BOTH - if they are present. The Supravision file format can have either XYZ data or BENDER data or BOTH. MiiC can transfer both sets of data. XYZ is not needed to operate the bender - only the PRB data. However, some customers rely on XYZ data as a revision cross-check. If Benderlink for MiiC finds XYZ data in the Supravision file, then it will import the XYZ data.

Any other data in SV format?

  • The SV file format also includes other items that may be in the file. For example, the part number, the tube diameter, the tube length are all usually in the file. This data is imported into Benderlink for MiiC also.

What happens at import of the Supravision Data File?

  • When Benderlink for Miic imports the Supravision data, a conversion to the MiiC bender format is automatic. This allows the operator to view, further edit, and then send the imported data directly to a MiiC bender.

Benderlink for MiiC Format

  • Benderlink for MiiC also has our own file format designed for storage of all the data on the MiiC control. (The Supravision file format will not save all options in the MiiC data - only the basics listed above.)

Tubecad Supravision File Output Sample

  • Click here to download a sample SUPRAVISION file created by Tubecad Pro. Use it to test conversion to other software that read Supravision files.